Vol 23, No 4 (2018)
Original research articles
Published online: 2018-07-01
Intensity-modulated radiation therapy and volumetric modulated arc therapy versus conventional conformal techniques at high energy: Dose assessment and impact on second primary cancer in the out-of-field region
DOI: 10.1016/j.rpor.2018.04.008
Rep Pract Oncol Radiother 2018;23(4):251-259.
Abstract
The aim of this work was to estimate peripheral neutron and photon doses associated with the conventional 3D conformal radiotherapy techniques in comparison to modern ones such as Intensity modulated radiation therapy and volumetric modulated arc therapy. Assessment in terms of second cancer incidence ought to peripheral doses was also considered. For that, a dosimetric methodology proposed by the authors has been applied beyond the region where there is no CT information and, thus, treatment planning systems do not calculate and where, nonetheless, about one third of second primary cancers occurs.
Keywords: Second primary cancerPeripheral doses in radiotherapy