open access

Vol 22, No 5 (2017)
Original research articles
Published online: 2017-09-01
Submitted: 2017-01-06
Get Citation

Evaluation of dose calculations accuracy of a commercial treatment planning system for the head and neck region in radiotherapy

Mohammad Taghi Bahreyni Toossi, Bagher Farhood, Shokouhozaman Soleymanifard
DOI: 10.1016/j.rpor.2017.06.001
·
Rep Pract Oncol Radiother 2017;22(5):420-427.

open access

Vol 22, No 5 (2017)
Original research articles
Published online: 2017-09-01
Submitted: 2017-01-06

Abstract

Aim

The objective was to quantify dose calculation accuracy of TiGRT TPS for head and neck region in radiotherapy.

Background

In radiotherapy of head and neck cancers, treatment planning is difficult, due to the complex shape of target volumes and also to spare critical and normal structures. These organs are often very near to the target volumes and have low tolerance to radiation. In this regard, dose calculation accuracy of treatment planning system (TPS) must be high enough.

Materials and methods

Thermoluminescent dosimeter-100 (TLD-100) chips were used within RANDO phantom for dose measurement. TiGRT TPS was also applied for dose calculation. Finally, difference between measured doses (Dmeas) and calculated doses (Dcalc) was obtained to quantify the dose calculation accuracy of the TPS at head and neck region.

Results

For in-field regions, in some points, the TiGRT TPS overestimated the dose compared to the measurements and for other points underestimated the dose. For outside field regions, the TiGRT TPS underestimated the dose compared to the measurements. For most points, the difference values between Dcalc and Dmeas for the in-field and outside field regions were less than 5% and 40%, respectively.

Conclusions

Due to the sensitive structures to radiation in the head and neck region, the dose calculation accuracy of TPSs should be sufficient. According to the results of this study, it is concluded that the accuracy of dose calculation of TiGRT TPS is enough for in-field and out of field regions.

Abstract

Aim

The objective was to quantify dose calculation accuracy of TiGRT TPS for head and neck region in radiotherapy.

Background

In radiotherapy of head and neck cancers, treatment planning is difficult, due to the complex shape of target volumes and also to spare critical and normal structures. These organs are often very near to the target volumes and have low tolerance to radiation. In this regard, dose calculation accuracy of treatment planning system (TPS) must be high enough.

Materials and methods

Thermoluminescent dosimeter-100 (TLD-100) chips were used within RANDO phantom for dose measurement. TiGRT TPS was also applied for dose calculation. Finally, difference between measured doses (Dmeas) and calculated doses (Dcalc) was obtained to quantify the dose calculation accuracy of the TPS at head and neck region.

Results

For in-field regions, in some points, the TiGRT TPS overestimated the dose compared to the measurements and for other points underestimated the dose. For outside field regions, the TiGRT TPS underestimated the dose compared to the measurements. For most points, the difference values between Dcalc and Dmeas for the in-field and outside field regions were less than 5% and 40%, respectively.

Conclusions

Due to the sensitive structures to radiation in the head and neck region, the dose calculation accuracy of TPSs should be sufficient. According to the results of this study, it is concluded that the accuracy of dose calculation of TiGRT TPS is enough for in-field and out of field regions.

Get Citation

Keywords

Head and neck region; Radiotherapy; Dose calculation accuracy; Treatment planning system

About this article
Title

Evaluation of dose calculations accuracy of a commercial treatment planning system for the head and neck region in radiotherapy

Journal

Reports of Practical Oncology and Radiotherapy

Issue

Vol 22, No 5 (2017)

Pages

420-427

Published online

2017-09-01

DOI

10.1016/j.rpor.2017.06.001

Bibliographic record

Rep Pract Oncol Radiother 2017;22(5):420-427.

Keywords

Head and neck region
Radiotherapy
Dose calculation accuracy
Treatment planning system

Authors

Mohammad Taghi Bahreyni Toossi
Bagher Farhood
Shokouhozaman Soleymanifard

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By "Via Medica sp. z o.o." sp.k., ul. Świętokrzyska 73, 80–180 Gdańsk, Poland
tel.:+48 58 320 94 94, fax:+48 58 320 94 60, e-mail: journals@viamedica.pl