Volumetric Modulated Arc Therapy (VMAT) make a difference in retro-orbital irradiation treatment of patients with bilateral Graves’ ophthalmopathy. Comparative analysis of dosimetric parameters from different radiation techniques

Iñigo San-Miguel, Ruth Carmona, Luis Luque, Raquel Cabrera, Marta Lloret, Francisco Rutllan, Pedro Carlos Lara
DOI: 10.1016/j.rpor.2016.03.001
·
Rep Pract Oncol Radiother 2016;21(5):435-440.

open access

Vol 21, No 5 (2016)
Original research articles
Published online: 2016-09-01
Submitted: 2015-07-26

Abstract

Background

Graves’ ophthalmopathy is the commonest extrathyroidal manifestation of Graves’ disease. Treatment options include steroid therapy, corrective/decompressive surgery, radiation therapy or combination of these approaches.

Aim

Our purpose was to investigate if retro-orbital irradiation with Volumetric Modulated Arc Therapy (VMAT) yielded better target coverage and dose sparing to adjacent normal structures compared to 3-Dimensional Conformal Radiotherapy (3DCRT) and Lateral Opposing Conformed Fields (LOCF).

Methods

Fourteen consecutive patients diagnosed with bilateral Graves’ ophthalmopathy were prospectively recruited into this study from August 2012 until August 2014. An individual VMAT, 3DCRT and LOF plan was created for each patient. Conformity Index (CI), Homogeneity Index (HI) and other dosimetric parameters of the targets and organs-at-risk (OAR) were analyzed in all 28 orbits compared between the different techniques.

Results

CI generated by VMAT was superior to that produced by 3DCRT(p[[ce:hsp sp="0.25"/]]<[[ce:hsp sp="0.25"/]].001) and LOF (p[[ce:hsp sp="0.25"/]]<[[ce:hsp sp="0.25"/]].001). As expected, 3DCRT was also superior to LOF (p[[ce:hsp sp="0.25"/]]=[[ce:hsp sp="0.25"/]].007). Regarding the OARs sparing dose (lens, globes, retina and lacrimal glands), VMAT showed a significant benefit when compared with 3DCRT and LOCF, with no differences between the two latter techniques.

Conclusions

VMAT should be preferred over 3DCRT and LOF for bilateral Graves’ ophthalmopathy treatment.

Abstract

Background

Graves’ ophthalmopathy is the commonest extrathyroidal manifestation of Graves’ disease. Treatment options include steroid therapy, corrective/decompressive surgery, radiation therapy or combination of these approaches.

Aim

Our purpose was to investigate if retro-orbital irradiation with Volumetric Modulated Arc Therapy (VMAT) yielded better target coverage and dose sparing to adjacent normal structures compared to 3-Dimensional Conformal Radiotherapy (3DCRT) and Lateral Opposing Conformed Fields (LOCF).

Methods

Fourteen consecutive patients diagnosed with bilateral Graves’ ophthalmopathy were prospectively recruited into this study from August 2012 until August 2014. An individual VMAT, 3DCRT and LOF plan was created for each patient. Conformity Index (CI), Homogeneity Index (HI) and other dosimetric parameters of the targets and organs-at-risk (OAR) were analyzed in all 28 orbits compared between the different techniques.

Results

CI generated by VMAT was superior to that produced by 3DCRT(p[[ce:hsp sp="0.25"/]]<[[ce:hsp sp="0.25"/]].001) and LOF (p[[ce:hsp sp="0.25"/]]<[[ce:hsp sp="0.25"/]].001). As expected, 3DCRT was also superior to LOF (p[[ce:hsp sp="0.25"/]]=[[ce:hsp sp="0.25"/]].007). Regarding the OARs sparing dose (lens, globes, retina and lacrimal glands), VMAT showed a significant benefit when compared with 3DCRT and LOCF, with no differences between the two latter techniques.

Conclusions

VMAT should be preferred over 3DCRT and LOF for bilateral Graves’ ophthalmopathy treatment.

Get Citation

Keywords

Graves’ opthalmopathy; Radiotherapy; VMAT; Dosimetric parameters

About this article
Title

Volumetric Modulated Arc Therapy (VMAT) make a difference in retro-orbital irradiation treatment of patients with bilateral Graves’ ophthalmopathy. Comparative analysis of dosimetric parameters from different radiation techniques

Journal

Reports of Practical Oncology and Radiotherapy

Issue

Vol 21, No 5 (2016)

Pages

435-440

Published online

2016-09-01

DOI

10.1016/j.rpor.2016.03.001

Bibliographic record

Rep Pract Oncol Radiother 2016;21(5):435-440.

Keywords

Graves’ opthalmopathy
Radiotherapy
VMAT
Dosimetric parameters

Authors

Iñigo San-Miguel
Ruth Carmona
Luis Luque
Raquel Cabrera
Marta Lloret
Francisco Rutllan
Pedro Carlos Lara

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By "Via Medica sp. z o.o." sp.k., ul. Świętokrzyska 73, 80–180 Gdańsk, Poland
tel.:+48 58 320 94 94, fax:+48 58 320 94 60, e-mail: journals@viamedica.pl