Dose-dependent vascular response following delivery of sirolimus via fast releasing, biodegradable polymer stent matrix: an experimental study in the porcine coronary model of restenosis

Piotr P. Buszman, Bartłomiej Orlik, Jacek Pająk, Michał Jelonek, Agata Krauze, Adam Janas, Jacek Legutko, Wojciech Wojakowski, Paweł E. Buszman, Krzysztof Milewski
Kardiol Pol 2015;73(10):916-923.

Abstract

Background: Fast releasing, rapamycin-eluting stents, although safe, showed inferior results with regard to inhibition of restenosis.

Aim: Therefore, we report vascular effects of a novel, biodegradable polymer stent matrix with elevated sirolimus dose and fast release kinetics (ed-frSES, Alex, Balton) in the porcine coronary in-stent restenosis model.

Methods: A total of 19 stents were implanted with 120% overstretch in the coronary arteries of seven domestic pigs: seven ed-frSES with 1.3 μg/mm2 of sirolimus, eight frSES with 1 μg/mm2 of sirolimus, and eight bare metal stents (BMS). For the following 28 days, coronary angiography was performed, animals were sacrificed, and the stented segments harvested for histopathological evaluation.

Results: In angiography at 28 days the late lumen loss was lowest in the elevated dose sirolimus eluting stent (SES) (ed-frSES: 0.20 ± 0.2 vs. frSES: 0.80 ± 0.5 vs. BMS: 0.96 ± 0.5 mm, p < 0.01). This was confirmed in the morphometric evaluation in histopathology as represented by a significant and dose-dependent decrease in the percentage area of stenosis (ed-frSES: 22.4 ± 12.7% vs. frSES: 35 ± 10.7% vs. BMS: 47.5 ± 12.5%, p < 0.01). There was no peri-strut inflammation in any of the groups. However, the endothelialisation score was numerically not meaningfully decreased in ed-frSES (ed-frSES: 2.93 vs. frSES: 3. vs. BMS: 3, p = 0.05). Signs of fibrin were also noted in ed-frSES (ed-frSES: 0.4 vs. frSES: 0 vs. BMS: 0, p = 0.05).

Conclusions: Sirolimus dose-dependent vascular response was reported. The elevated dose, fast releasing SES shows satisfac­tory vascular healing, similar to regular dose, fast release SES, with improved efficacy in restenosis inhibition.