Transcatheter implantation of Edwards-SAPIEN THV valve in pulmonary position
DOI: 10.33963/v.kp.79264
Kardiol Pol 2011;69(7):749-750.
Abstract
Transcatheter pulmonary valve implantation improves conduit haemodynamics without necessity of complex reoperation.
Clinical experience with application of the Edwards-SAPIEN Transcatheter Heart Valve (THV) in pulmonary position is still
limited. We present data of 2 patients (21 year-old woman and 26 year-old man) with a history of dysfunction of homograft
in position of right ventricular outflow tract (RVOT), in whom the Edwards-SAPIEN THV was successfuly implanted.
Kardiol Pol 2011; 69, 7: 749–750
Kardiol Pol 2011; 69, 7: 749–750
Keywords: interventional cardiologypulmonary homograftEdwards-SAPIEN THV