Vol 69, No 9 (2011)
Invasive electrophysiology
Published online: 2011-09-19

open access

Page views 463
Article views/downloads 713
Get Citation

Connect on Social Media

Connect on Social Media

Transvenous extraction of pacing system in a patient after Senning operation for transposition of great arteries

Maciej Kempa, Marta Piepiorka, Rafał Pawlaczyk, Szymon Budrejko, Joanna Kwiatkowska, Jan Rogowski, Grzegorz Raczak
DOI: 10.33963/v.kp.79191
Kardiol Pol 2011;69(9):974-976.

Abstract

We present a case of a 33 year-old patient with transposition of great arteries, treated in the past with Senning operation, who had undergone a DDD pacemaker implatation procedure. The patient was subjected to transcutaneous removal of the pacing system due to infection, with a concurrent implantation of a pacemker with epicardial pacing leads.
Kardiol Pol 2011; 69, 9: 974–976

Article available in PDF format

View PDF (Polish) Download PDF file