Abstract

INTRODUCTION. Normal temporal contrast sensitivity is maximally influenced by pre-adaptation with 25-Hz temporal contrast flicker. The aim of this study was to investigate the effects of 25-Hz contrast adaptation on recovery of contrast sensitivity in normals, patients with ocular hypertension, preperimetric, perimetric and advanced perimetric open-angle glaucoma.

MATERIALS AND METHODS. Temporal contrast sensitivity was examined after pre-adaptation with 25 Hz in the following: 43 normals, 14 ocular hypertension, 10 preperimetric primary open-angle glaucoma, and 33 perimetric open-an­gle glaucoma patients. After pre-adaptation (the time after which a test stimulus could be detected again), recovery time (RT) was measured at 3% and 5% test contrast. Additionally, 25 patients with advanced perimetric open-angle glaucoma were measured at 12%, 25%, and 35% contrast and compared to a normal group consisting of 15 subjects.

RESULTS. 1. Measurements of RT are reliable (Cronbach’s a > 0.8). 2. RT was age-dependent requiring an age-correction in further analyses. 3. RT3% and RT5% were significantly prolonged in perimetric primary open-angle glau­coma compared to normals (3% test contrast: p = 0.007; 5% test contrast: p = 0.035). 4. Within each group, RT3% and RT5% were significantly different at both test contrasts (normals, perimetric open-angle glaucoma: p < 0.001; ocular hypertension: p = 0.007; preperimetric open-angle glaucoma: p = 0.035). 5. RT3% and RT5% were significantly correlated with mean defect (p < 0.001) and retinal nerve fibre layer thickness (p = 0.018). RT5% was correlated with loss variance (p = 0.048). 6. RT12%, RT25% and RT35% were significantly prolonged in advanced perimetric glaucoma (p < 0.001), and correlated with mean defect (p < 0.001, p = 0.002, p = 0.013) and retinal nerve fibre layer thickness (p < 0.001, p = 0.003, p = 0.013). RT12% was also correlated with loss variance (p = 0.016).

CONCLUSIONS. Measurements of RT after 25-Hz pre-adaptation can be used in glaucoma diagnosis and follow-up examination, especially in monitoring glaucoma progress in advanced perimetric primary open-angle glaucoma.

Abstract

INTRODUCTION. Normal temporal contrast sensitivity is maximally influenced by pre-adaptation with 25-Hz temporal contrast flicker. The aim of this study was to investigate the effects of 25-Hz contrast adaptation on recovery of contrast sensitivity in normals, patients with ocular hypertension, preperimetric, perimetric and advanced perimetric open-angle glaucoma.

MATERIALS AND METHODS. Temporal contrast sensitivity was examined after pre-adaptation with 25 Hz in the following: 43 normals, 14 ocular hypertension, 10 preperimetric primary open-angle glaucoma, and 33 perimetric open-an­gle glaucoma patients. After pre-adaptation (the time after which a test stimulus could be detected again), recovery time (RT) was measured at 3% and 5% test contrast. Additionally, 25 patients with advanced perimetric open-angle glaucoma were measured at 12%, 25%, and 35% contrast and compared to a normal group consisting of 15 subjects.

RESULTS. 1. Measurements of RT are reliable (Cronbach’s a > 0.8). 2. RT was age-dependent requiring an age-correction in further analyses. 3. RT3% and RT5% were significantly prolonged in perimetric primary open-angle glau­coma compared to normals (3% test contrast: p = 0.007; 5% test contrast: p = 0.035). 4. Within each group, RT3% and RT5% were significantly different at both test contrasts (normals, perimetric open-angle glaucoma: p < 0.001; ocular hypertension: p = 0.007; preperimetric open-angle glaucoma: p = 0.035). 5. RT3% and RT5% were significantly correlated with mean defect (p < 0.001) and retinal nerve fibre layer thickness (p = 0.018). RT5% was correlated with loss variance (p = 0.048). 6. RT12%, RT25% and RT35% were significantly prolonged in advanced perimetric glaucoma (p < 0.001), and correlated with mean defect (p < 0.001, p = 0.002, p = 0.013) and retinal nerve fibre layer thickness (p < 0.001, p = 0.003, p = 0.013). RT12% was also correlated with loss variance (p = 0.016).

CONCLUSIONS. Measurements of RT after 25-Hz pre-adaptation can be used in glaucoma diagnosis and follow-up examination, especially in monitoring glaucoma progress in advanced perimetric primary open-angle glaucoma.

Get Citation

Keywords

glaucoma, ocular hypertension, flicker adaptation, recovery time, temporal contrast sensitivity, advanced glaucoma

About this article
Title

25 Hz adaptation: Influence on recovery time in glaucoma

Journal

Ophthalmology Journal

Issue

Vol 1, No 1 (2016)

Article type

Original paper

Pages

1-9

Published online

2016-03-30

Page views

901

Article views/downloads

827

DOI

10.5603/OJ.2016.0001

Bibliographic record

Ophthalmol J 2016;1(1):1-9.

Keywords

glaucoma
ocular hypertension
flicker adaptation
recovery time
temporal contrast sensitivity
advanced glaucoma

Authors

Katharina Brehmer
Pia Rutrecht
Simon Mißlinger
Anselm Jünemann
Folkert Horn
Jan Kremers
Bettina Hohberger

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

Publisher: VM Media Group sp. z o.o., Grupa Via Medica, 73 Świętokrzyska St., 80–180 Gdańsk

tel.:+48 58 310 94 94, faks:+48 58 320 94 60, e-mail: viamedica@viamedica.pl