open access

Vol 75, No 4 (2016)
Original article
Submitted: 2016-03-08
Accepted: 2016-04-15
Published online: 2016-04-25
Get Citation

A comparative approach to computer aided design model of a dog femur

O. Turamanlar, O. Verim, A. Karabulut
·
Pubmed: 27830879
·
Folia Morphol 2016;75(4):550-554.

open access

Vol 75, No 4 (2016)
ORIGINAL ARTICLES
Submitted: 2016-03-08
Accepted: 2016-04-15
Published online: 2016-04-25

Abstract

Computer assisted technologies offer new opportunities in medical imaging and rapid prototyping in biomechanical engineering. Three dimensional (3D) modelling of soft tissues and bones are becoming more important. The accuracy of the analysis in modelling processes depends on the outline of the tissues derived from medical images. The aim of this study is the evaluation of the accuracy of 3D models of a dog femur derived from computed tomography data by using point cloud method and boundary line method on several modelling software. Solidworks, Rapidform and 3DSMax software were used to create 3D models and outcomes were evaluated statistically. The most accurate 3D prototype of the dog femur was created with stereolithography method using rapid prototype device. Furthermore, the linearity of the volumes of models was investigated between software and the constructed models. The difference between the software and real models manifests the sensitivity of the software and the devices used in this manner.

Abstract

Computer assisted technologies offer new opportunities in medical imaging and rapid prototyping in biomechanical engineering. Three dimensional (3D) modelling of soft tissues and bones are becoming more important. The accuracy of the analysis in modelling processes depends on the outline of the tissues derived from medical images. The aim of this study is the evaluation of the accuracy of 3D models of a dog femur derived from computed tomography data by using point cloud method and boundary line method on several modelling software. Solidworks, Rapidform and 3DSMax software were used to create 3D models and outcomes were evaluated statistically. The most accurate 3D prototype of the dog femur was created with stereolithography method using rapid prototype device. Furthermore, the linearity of the volumes of models was investigated between software and the constructed models. The difference between the software and real models manifests the sensitivity of the software and the devices used in this manner.

Get Citation

Keywords

dog femur, iterative closest point algorithm, rapid prototype, root mean square, three dimensional modelling

About this article
Title

A comparative approach to computer aided design model of a dog femur

Journal

Folia Morphologica

Issue

Vol 75, No 4 (2016)

Article type

Original article

Pages

550-554

Published online

2016-04-25

Page views

1222

Article views/downloads

1021

DOI

10.5603/FM.a2016.0023

Pubmed

27830879

Bibliographic record

Folia Morphol 2016;75(4):550-554.

Keywords

dog femur
iterative closest point algorithm
rapid prototype
root mean square
three dimensional modelling

Authors

O. Turamanlar
O. Verim
A. Karabulut

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., Grupa Via Medica, Świętokrzyska 73, 80–180 Gdańsk, Poland

tel.: +48 58 320 94 94, faks: +48 58 320 94 60, e-mail: viamedica@viamedica.pl