Anatomy of coronary sinus ostium

J. Zhivadinovik, M. Papazova, N. Matveeva, A. Dodevski, B. Zafirova
·
Pubmed: 26431050
·
Folia Morphol 2016;75(2):264-267.

open access

Vol 75, No 2 (2016)
ORIGINAL ARTICLES
Submitted: 2015-07-22
Accepted: 2015-08-13
Published online: 2015-10-02

Abstract

Background: The coronary sinus is the main cardiac vein and it has become a clinically important structure especially through its role in providing access for different cardiac procedures.

Materials and methods: The study was carried out on 100 randomly selected adult human cadaver hearts fixed in 10% formalin. The transverse and craniocaudal diameters of the coronary sinus ostium (CSO) were directly measured. The presence of the Thebesian valve was noted and the anatomical details of the valve were documented in each case in terms of the shape and extent of coverage of the CSO.

Results: Considerable variations in the diameter of the CSO were observed. The mean craniocaudal diameter of the CSO was 8.1 ± 1.51 mm, and the mean transverse diameter was 7.67 ± 1.72 mm. Heart specimens without Thebesian valve tended to have larger ostia. The mean craniocaudal diameter and the mean transverse diameter of the CSO were statistically larger in the specimens without Thebesian valves (p = 0.000 and p = 0.001, respectively).

Conclusions: The Thebesian valves were observed in 86 hearts, and a wide variety of their morphology was seen. The majority of the Thebesian valves were semilunar in shape (74.42%). The extent to which the valve covered the ostium was variable, including remnant valves that covered < 15% of the CSO (35%), and valves that were large and covered at least 75% of the CSO (22.09%). In 3 specimens the valve completely occluded the ostium.  

Abstract

Background: The coronary sinus is the main cardiac vein and it has become a clinically important structure especially through its role in providing access for different cardiac procedures.

Materials and methods: The study was carried out on 100 randomly selected adult human cadaver hearts fixed in 10% formalin. The transverse and craniocaudal diameters of the coronary sinus ostium (CSO) were directly measured. The presence of the Thebesian valve was noted and the anatomical details of the valve were documented in each case in terms of the shape and extent of coverage of the CSO.

Results: Considerable variations in the diameter of the CSO were observed. The mean craniocaudal diameter of the CSO was 8.1 ± 1.51 mm, and the mean transverse diameter was 7.67 ± 1.72 mm. Heart specimens without Thebesian valve tended to have larger ostia. The mean craniocaudal diameter and the mean transverse diameter of the CSO were statistically larger in the specimens without Thebesian valves (p = 0.000 and p = 0.001, respectively).

Conclusions: The Thebesian valves were observed in 86 hearts, and a wide variety of their morphology was seen. The majority of the Thebesian valves were semilunar in shape (74.42%). The extent to which the valve covered the ostium was variable, including remnant valves that covered < 15% of the CSO (35%), and valves that were large and covered at least 75% of the CSO (22.09%). In 3 specimens the valve completely occluded the ostium.  

Get Citation

Keywords

Thebesian valve, coronary sinus ostium, variations

About this article
Title

Anatomy of coronary sinus ostium

Journal

Folia Morphologica

Issue

Vol 75, No 2 (2016)

Article type

Original article

Pages

264-267

Published online

2015-10-02

Page views

1682

Article views/downloads

1778

DOI

10.5603/FM.a2015.0089

Pubmed

26431050

Bibliographic record

Folia Morphol 2016;75(2):264-267.

Keywords

Thebesian valve
coronary sinus ostium
variations

Authors

J. Zhivadinovik
M. Papazova
N. Matveeva
A. Dodevski
B. Zafirova

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., Grupa Via Medica, Świętokrzyska 73, 80–180 Gdańsk, Poland

tel.: +48 58 320 94 94, faks: +48 58 320 94 60, e-mail: viamedica@viamedica.pl