open access

Vol 66, No 6 (2015)
Original paper
Submitted: 2014-12-16
Accepted: 2015-05-27
Published online: 2015-12-07
Get Citation

Incidentally recognised thyroid focal uptake of 99mTc-sestamibi during stress myocardial perfusion scintigraphy

Krzysztof Giejda, Stanisław Piszczek, Zofia Stembrowicz-Nowakowska, Marek Saracyn, Mirosław Dziuk, Grzegorz Kamiński
DOI: 10.5603/EP.2015.0064
·
Pubmed: 26662651
·
Endokrynol Pol 2015;66(6):521-525.

open access

Vol 66, No 6 (2015)
Original Paper
Submitted: 2014-12-16
Accepted: 2015-05-27
Published online: 2015-12-07

Abstract

Introduction: 99mTc-sestamibi, a radiopharmaceutical widely used in the assessment of myocardial perfusion, can be used as an indicator of thyroid disease due to its oncophilic character. The aim of this study was to establish the usefulness of performing additional examinations of radiotracer uptake in the thyroid gland during standard stress scintigraphy with sestamibi in order to identify thyroid diseases.

Material and methods: After a retrospective evaluation of 330 consecutive myocardial perfusion scintigraphies performed in our hospital during one year, 41 patients with a focal accumulation of 99mTc-sestamibi in the thyroid were enrolled in the study. The patients underwent clinical examinations, including thyroid ultrasonography and TSH, fT4, fT3, aTPO, TRAB, calcitonin, and CEA levels. Based on the thyroid ultrasounds, 21 patients were referred for fine-needle aspiration biopsy of the thyroid.

Results: An abnormal accumulation of radiotracer in the thyroid was found in 41(12.4%) of 330 patients who underwent stress cardiac scintigraphy. Thirteen (31.7%) of those patients had multinodular euthyroid goitres, 12 (29.2%) had a single thyroid nodule (including two autonomous nodules), 11 (26.8%) had autoimmune thyroid disease, and one (2.4%) had papillary thyroid carcinoma. In 12 (29.2%) with thyroid tracer uptake there was no thyroid pathology.

Conclusions:

  1. Additional evaluation of radiotracer uptake in the thyroid during standard myocardial perfusion scintigraphy is a valuable tool in the detection of thyroid diseases.
  2. The additional or parallel evaluation of radiotracer uptake in the thyroid should be considered during every myocardial scintigraphy. (Endokrynol Pol 2015; 66 (6): 521–525)

Abstract

Introduction: 99mTc-sestamibi, a radiopharmaceutical widely used in the assessment of myocardial perfusion, can be used as an indicator of thyroid disease due to its oncophilic character. The aim of this study was to establish the usefulness of performing additional examinations of radiotracer uptake in the thyroid gland during standard stress scintigraphy with sestamibi in order to identify thyroid diseases.

Material and methods: After a retrospective evaluation of 330 consecutive myocardial perfusion scintigraphies performed in our hospital during one year, 41 patients with a focal accumulation of 99mTc-sestamibi in the thyroid were enrolled in the study. The patients underwent clinical examinations, including thyroid ultrasonography and TSH, fT4, fT3, aTPO, TRAB, calcitonin, and CEA levels. Based on the thyroid ultrasounds, 21 patients were referred for fine-needle aspiration biopsy of the thyroid.

Results: An abnormal accumulation of radiotracer in the thyroid was found in 41(12.4%) of 330 patients who underwent stress cardiac scintigraphy. Thirteen (31.7%) of those patients had multinodular euthyroid goitres, 12 (29.2%) had a single thyroid nodule (including two autonomous nodules), 11 (26.8%) had autoimmune thyroid disease, and one (2.4%) had papillary thyroid carcinoma. In 12 (29.2%) with thyroid tracer uptake there was no thyroid pathology.

Conclusions:

  1. Additional evaluation of radiotracer uptake in the thyroid during standard myocardial perfusion scintigraphy is a valuable tool in the detection of thyroid diseases.
  2. The additional or parallel evaluation of radiotracer uptake in the thyroid should be considered during every myocardial scintigraphy. (Endokrynol Pol 2015; 66 (6): 521–525)
Get Citation

Keywords

thyroid nodules; sestamibi; myocardial scintigraphy; thyroid cancer; thyroid autoimmune disease

About this article
Title

Incidentally recognised thyroid focal uptake of 99mTc-sestamibi during stress myocardial perfusion scintigraphy

Journal

Endokrynologia Polska

Issue

Vol 66, No 6 (2015)

Article type

Original paper

Pages

521-525

Published online

2015-12-07

Page views

1371

Article views/downloads

1863

DOI

10.5603/EP.2015.0064

Pubmed

26662651

Bibliographic record

Endokrynol Pol 2015;66(6):521-525.

Keywords

thyroid nodules
sestamibi
myocardial scintigraphy
thyroid cancer
thyroid autoimmune disease

Authors

Krzysztof Giejda
Stanisław Piszczek
Zofia Stembrowicz-Nowakowska
Marek Saracyn
Mirosław Dziuk
Grzegorz Kamiński

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

Via MedicaWydawcą jest  VM Media Group sp. z o.o., Grupa Via Medica, ul. Świętokrzyska 73, 80–180 Gdańsk

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail:  viamedica@viamedica.pl