The utility of serum glucose measurement at 1 hour of the oral glucose tolerance test

Ewa Otto-Buczkowska, Marek Dryżałowski
DOI: 10.5603/DK.2016.0022
·
Clinical Diabetology 2016;5(4):127-130.

open access

Vol 5, No 4 (2016)
Review
Published online: 2016-11-03

Abstract

The oral glucose tolerance test (OGTT) is performed in patients in whom abnormalities of glucose metabolism are suspected, but the criteria for diagnosing diabetes are not yet met. It is also routinely carried out in the management of diseases associated with a more or less pronounced disturbance of glucose intolerance. According to the current guidelines, during OGTT glycemia is measured before and two hours after the administration of glucose. In pregnancy, three measurements are obligatory (0’, 60’, 120’). When additional indications are present, glycemia is assessed also 30 minutes after the administration of glucose and when reactive hypoglycemia is suspected, the test is extended to 180 minutes. As of late, it is becoming a more and more common practice to measure blood glucose also 60 minutes post-administration. This technique is more reliable for the assessment of glucose tolerance disturbance. It seems sensible to introduce a recommendation of such measurement as a routine practice.

Abstract

The oral glucose tolerance test (OGTT) is performed in patients in whom abnormalities of glucose metabolism are suspected, but the criteria for diagnosing diabetes are not yet met. It is also routinely carried out in the management of diseases associated with a more or less pronounced disturbance of glucose intolerance. According to the current guidelines, during OGTT glycemia is measured before and two hours after the administration of glucose. In pregnancy, three measurements are obligatory (0’, 60’, 120’). When additional indications are present, glycemia is assessed also 30 minutes after the administration of glucose and when reactive hypoglycemia is suspected, the test is extended to 180 minutes. As of late, it is becoming a more and more common practice to measure blood glucose also 60 minutes post-administration. This technique is more reliable for the assessment of glucose tolerance disturbance. It seems sensible to introduce a recommendation of such measurement as a routine practice.

Get Citation

Keywords

prediabetic state, diabetes mellitus, oral glucose tolerance test, glucose intolerance, clinical cases

About this article
Title

The utility of serum glucose measurement at 1 hour of the oral glucose tolerance test

Journal

Clinical Diabetology

Issue

Vol 5, No 4 (2016)

Pages

127-130

Published online

2016-11-03

DOI

10.5603/DK.2016.0022

Bibliographic record

Clinical Diabetology 2016;5(4):127-130.

Keywords

prediabetic state
diabetes mellitus
oral glucose tolerance test
glucose intolerance
clinical cases

Authors

Ewa Otto-Buczkowska
Marek Dryżałowski

References (17)
  1. Diagnosis and Classification of Diabetes Mellitus. Diabetes Care. 2012; 36(Supplement_1): S67–S74.
  2. Zalecenia kliniczne dotyczące postępowania u chorych na cukrzycę na rok 2015 PTD. Diabetologia Kliniczna. 2015; 4(Suppl A).
  3. Wand H, Calmy A, Carey DL, et al. INITIO Trial International Coordinating Committee, Expert Committee on the Diagnosis and Classification of Diabetes Mellitus. Follow-up report on the diagnosis of diabetes mellitus. Diabetes Care. 2003; 26(11): 3160–3167.
  4. Seino Y, Nanjo K, Tajima N, et al. Committee of the Japan Diabetes Society on the Diagnostic Criteria of Diabetes Mellitus. Report of the committee on the classification and diagnostic criteria of diabetes mellitus. J Diabetes Investig. 2010; 1(5): 212–228.
  5. Cypryk K, Lewandowski K, Szosland K, Skowrońska-Jóźwiak E, Lewinski A. Ocena czynności wewnątrzwydzielniczej trzustki. In: Pietrzyk JJ, Szajewska H, Mrukowicz J. ed. ABC zabiegów w pediatrii. Medycyna Praktyczna, Kraków 2010: 129–142.
  6. Nguyen QM, Srinivasan SR, Xu JH, et al. Fasting plasma glucose levels within the normoglycemic range in childhood as a predictor of prediabetes and type 2 diabetes in adulthood: the Bogalusa Heart Study. Arch Pediatr Adolesc Med. 2010; 164(2): 124–128.
  7. Jarosz-Chobot P, Otto-Buczkowska E. Wybrane procedury diagnostyczne w zaburzeniach gospodarki węglowodanowej. In: Pietrzyk JJ, Szajewska H, Mrukowicz J. ed. ABC zabiegów w pediatrii. Medycyna Praktyczna, Kraków 2010: 195.
  8. Abdul-Ghani MA, Abdul-Ghani T, Ali N, et al. One-hour plasma glucose concentration and the metabolic syndrome identify subjects at high risk for future type 2 diabetes. Diabetes Care. 2008; 31(8): 1650–1655.
  9. Abdul-Ghani MA, Lyssenko V, Tuomi T, et al. Fasting versus postload plasma glucose concentration and the risk for future type 2 diabetes: results from the Botnia Study. Diabetes Care. 2009; 32(2): 281–286.
  10. Abdul-Ghani MA, Stern MP, Lyssenko V, et al. Minimal contribution of fasting hyperglycemia to the incidence of type 2 diabetes in subjects with normal 2-h plasma glucose. Diabetes Care. 2010; 33(3): 557–561.
  11. Oh T, Min S, Ahn C, et al. Normal Glucose Tolerance with a High 1-Hour Postload Plasma Glucose Level Exhibits Decreased β-Cell Function Similar to Impaired Glucose Tolerance. Diabetes & Metabolism Journal. 2015; 39(2): 147.
  12. Manco M, Miraglia Del Giudice E, Spreghini MR, et al. 1-Hour plasma glucose in obese youth. Acta Diabetol. 2012; 49(6): 435–443.
  13. Wu X, Chen H, Wang Y, et al. The relationship between coronary risk factors and elevated 1-h postload plasma glucose levels in patients with established coronary heart disease. Clin Endocrinol (Oxf). 2013; 78(1): 67–72.
  14. Su JB, Chen T, Xu F, et al. Glycemic variability in normal glucose regulation subjects with elevated 1-h postload plasma glucose levels. Endocrine. 2014; 46(2): 241–248.
  15. Priya MM, Amutha A, Pramodkumar TA, et al. β-Cell Function and Insulin Sensitivity in Normal Glucose-Tolerant Subjects Stratified by 1-Hour Plasma Glucose Values. Diabetes Technol Ther. 2016; 18(1): 29–33.
  16. Succurro E, Arturi F, Lugarà M, et al. One-hour postload plasma glucose levels are associated with kidney dysfunction. Clin J Am Soc Nephrol. 2010; 5(11): 1922–1927.
  17. Kuang L, Huang Z, Hong Z, et al. Predictability of 1-h postload plasma glucose concentration: A 10-year retrospective cohort study. J Diabetes Investig. 2015; 6(6): 647–654.

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

 

Wydawcą serwisu jest  "Via Medica sp. z o.o." sp.k., ul. Świętokrzyska 73, 80–180 Gdańsk

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail:  viamedica@viamedica.pl