open access

Vol 10, No 2 (2009): Practical Diabetology
Original articles (submitted)
Published online: 2009-06-25
Get Citation

Standarisation of laser Doppler flowmetry - own standards

Robert Liana, Marek Chudański, Irena Ponikowska
Diabetologia Praktyczna 2009;10(2):58-64.

open access

Vol 10, No 2 (2009): Practical Diabetology
Original articles (submitted)
Published online: 2009-06-25

Abstract

INTRODUCTION. The aim of this investigation was to designate own standards of microcirculation parameters. Despite of lack of credible standards in polish science we assessed nine microcirculation parameters in healthy subject.
MATERIAL AND METHODS. There were analyzed 40 young people (80 measurements), 27 men and 13 women were involved, mean age was 24.6 (SD 7.1). The subject fold up healthy volunteers main students. There was made methodology analyzes and investigated particular parameters. In everyone was designated 9 parameters in the rest, during occlusion test and after finishing it. We used one pointed scanner PIM II version, Perimed, Sweden. We investigated 2 limbs in everyone on the top of big toe.
RESULTS. In the table are mean values parameters with standard deviation and range of the norms.
CONCLUSIONS. Among 9 designated parameters statistical powerful was: RF, BZ, maximal hyperemia MAX, TM, TH and BZ/RF indicator. Designated standards for one pointed scanner method can be use in practice and diagnostic and are reference to patients with microcirculatory disturbances.

Abstract

INTRODUCTION. The aim of this investigation was to designate own standards of microcirculation parameters. Despite of lack of credible standards in polish science we assessed nine microcirculation parameters in healthy subject.
MATERIAL AND METHODS. There were analyzed 40 young people (80 measurements), 27 men and 13 women were involved, mean age was 24.6 (SD 7.1). The subject fold up healthy volunteers main students. There was made methodology analyzes and investigated particular parameters. In everyone was designated 9 parameters in the rest, during occlusion test and after finishing it. We used one pointed scanner PIM II version, Perimed, Sweden. We investigated 2 limbs in everyone on the top of big toe.
RESULTS. In the table are mean values parameters with standard deviation and range of the norms.
CONCLUSIONS. Among 9 designated parameters statistical powerful was: RF, BZ, maximal hyperemia MAX, TM, TH and BZ/RF indicator. Designated standards for one pointed scanner method can be use in practice and diagnostic and are reference to patients with microcirculatory disturbances.
Get Citation

Keywords

laser Doppler flowmetry; microcirculation; standardization

About this article
Title

Standarisation of laser Doppler flowmetry - own standards

Journal

Clinical Diabetology

Issue

Vol 10, No 2 (2009): Practical Diabetology

Pages

58-64

Published online

2009-06-25

Bibliographic record

Diabetologia Praktyczna 2009;10(2):58-64.

Keywords

laser Doppler flowmetry
microcirculation
standardization

Authors

Robert Liana
Marek Chudański
Irena Ponikowska

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

Czasopismo Diabetologia Kliniczna dostęne jest również w Ikamed - księgarnia medyczna

Wydawcą serwisu jest  "Via Medica sp. z o.o." sp.k., ul. Świętokrzyska 73, 80–180 Gdańsk

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail:  viamedica@viamedica.pl