open access

Vol 18, No 6 (2011)
Original articles
Submitted: 2013-01-14
Published online: 2011-11-23
Get Citation

Intracoronary electrocardiogram ST segment shift evaluation during intravenous adenosine infusion: A comparison with fractional flow reserve

Vruyr Balian, Claudio Marcassa, Michele Galli, Gianni Cecchin, Riccardo Michi, Marco Crenna, Ettore Petrucci, Marco Onofri
DOI: 10.5603/cj.21178
·
Cardiol J 2011;18(6):662-667.

open access

Vol 18, No 6 (2011)
Original articles
Submitted: 2013-01-14
Published online: 2011-11-23

Abstract

Background: By measuring the pressure decline caused by coronary narrowing, fractional flow reserve (FFR) is an index of the physiological significance of a vessel stenosis. Intracoronary electrocardiogram (IC-ECG) recording from an angioplasty guidewire is more sensitive than standard ECG in detecting regional myocardial ischemia. The aim of the study was to assess if unipolar IC-ECG ST segment recording from angioplasty guidewire during maximal pharmacologic vasodilation could be used as an indirect estimation of FFR results.
Methods: Forty-eight clinically stable patients with intermediate stenosis underwent FFR evaluation and IC-ECG recording during intravenous adenosine infusion.
Results: FFR values were ≤ 0.80 in 26 (54%) patients and > 0.80 in 22 (46%). After adenosine, standard ECG was abnormal in only nine (19%) patients, while IC-ECG showed a significant ST segment shift (IST) in 24 (50%) patients: ST elevation in 19 patients and depression in five). IST was documented in 21/26 patients with FFR ≤ 0.80 (81%) and in 3/22 with FFR > 0.80 (p < 0.001). Sensitivity of IST for predicting an abnormal FFR value was 81%, specificity 86%, positive and negative predictive accuracies were 88% and 79%, respectively.
Conclusions: Intracoronary ST segment shift evaluation during adenosine infusion may be of value in assessing the functional significance of a borderline stenosis. The presence of IST during adenosine infusion could obviate the need for additional FFR evaluation. (Cardiol J 2011; 18, 6: 662–667)

Abstract

Background: By measuring the pressure decline caused by coronary narrowing, fractional flow reserve (FFR) is an index of the physiological significance of a vessel stenosis. Intracoronary electrocardiogram (IC-ECG) recording from an angioplasty guidewire is more sensitive than standard ECG in detecting regional myocardial ischemia. The aim of the study was to assess if unipolar IC-ECG ST segment recording from angioplasty guidewire during maximal pharmacologic vasodilation could be used as an indirect estimation of FFR results.
Methods: Forty-eight clinically stable patients with intermediate stenosis underwent FFR evaluation and IC-ECG recording during intravenous adenosine infusion.
Results: FFR values were ≤ 0.80 in 26 (54%) patients and > 0.80 in 22 (46%). After adenosine, standard ECG was abnormal in only nine (19%) patients, while IC-ECG showed a significant ST segment shift (IST) in 24 (50%) patients: ST elevation in 19 patients and depression in five). IST was documented in 21/26 patients with FFR ≤ 0.80 (81%) and in 3/22 with FFR > 0.80 (p < 0.001). Sensitivity of IST for predicting an abnormal FFR value was 81%, specificity 86%, positive and negative predictive accuracies were 88% and 79%, respectively.
Conclusions: Intracoronary ST segment shift evaluation during adenosine infusion may be of value in assessing the functional significance of a borderline stenosis. The presence of IST during adenosine infusion could obviate the need for additional FFR evaluation. (Cardiol J 2011; 18, 6: 662–667)
Get Citation

Keywords

angioplasty; electrocardiography; revascularization; adenosine

About this article
Title

Intracoronary electrocardiogram ST segment shift evaluation during intravenous adenosine infusion: A comparison with fractional flow reserve

Journal

Cardiology Journal

Issue

Vol 18, No 6 (2011)

Pages

662-667

Published online

2011-11-23

Page views

739

Article views/downloads

1424

DOI

10.5603/cj.21178

Bibliographic record

Cardiol J 2011;18(6):662-667.

Keywords

angioplasty
electrocardiography
revascularization
adenosine

Authors

Vruyr Balian
Claudio Marcassa
Michele Galli
Gianni Cecchin
Riccardo Michi
Marco Crenna
Ettore Petrucci
Marco Onofri

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., Grupa Via Medica, ul. Świętokrzyska 73, 80–180 Gdańsk, Poland
tel.:+48 58 320 94 94, fax:+48 58 320 94 60, e-mail: viamedica@viamedica.pl