We present a case of a 42-year-old female with a unicuspid aortic valve identified by echocardiography and confirmed by cardiac computed tomography. This woman was referred to our department for a diagnostic workup of progressive significant breathlessness at exercise and suspected arrhythmia. On admission, she was in stable clinical condition without significant abnormalities on physical examination except for a loud systolic murmur at the aortic valve.
Transthoracic echocardiography (2D TTE) showed a unicuspid unicommissural aortic valve with severe, high-gradient aortic stenosis. The aortic valve area (AVA) was 0.9 cm2 with peak velocity of 4.4 m/s with a mean gradient of 42 mmHg. Additional findings of mild aortic regurgitation and dilatation of the ascending aorta (51 mm) were made with no signs of aortic coarctation. Transesophageal echocardiography (2D, 3D TEE) confirmed the defect in the aortic valve. Findings were consistent with severe aortic stenosis. For surgical planning, the patient underwent a computed tomography (CT) scan which showed no evidence of coronary artery stenosis and confirmed unicuspid aortic valve.
During cardiac surgery, replacement of the unicuspid aortic valve was performed and a biological prosthesis was implanted. Moreover, the ascending aorta was replaced with a graft.
Unicuspid, unicommissural aortic valve is an extremely rare congenital anomaly of the aortic valve [1]. The estimated frequency of its occurrence is 0.02% and is 100 times less common than a bicuspid aortic valve (BAV). Importantly, unicuspid aortic valves are associated with rapid progression of valvular dysfunction and aortic dilatation.
In the case of our patient, the performed examinations (TTE, TEE CT) showed three major criteria for a unicuspid valve: single commissural zone of attachment, rounded leaflet-free edge on the opposite side of the commissural attachment zone, and eccentric valvular orifice during systole [2].
In conclusion, this case report confirms the steps that should be taken to accurately assess a rare defect like unicuspid aortic valves using accessible non-invasive methods.
Supplementary material
Supplementary material is available at https://journals.viamedica.pl/kardiologia_polska.
Article information
Conflict of interest: None declared.
Funding: None.
Open access: This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. For commercial use, please contact the journal office at kardiologiapolska@ptkardio.pl.