Vol 81, No 12 (2023)
Clinical vignette
Published online: 2023-12-21

open access

Page views 355
Article views/downloads 173
Get Citation

Connect on Social Media

Connect on Social Media

Atrial pacemaker implantation in an adult patient with Fontan circulation and chronotropic insufficiency

Krzysztof Boczar1, Andrzej Ząbek12, Lidia Tomkiewicz-Pająk23, Mateusz Ulman1, Jacek Lelakowski12
Pubmed: 38189513
Kardiol Pol 2023;81(12):1298-1299.

Abstract

Not available
22_HTML_KP_12_2023__Boczar___324
  • CLINICAL VIGNETTE

Atrial pacemaker implantation in an adult patient with Fontan circulation and chronotropic insufficiency

Krzysztof Boczar1, Andrzej Ząbek1, 2, Lidia Tomkiewicz-Pająk2, 3, Mateusz Ulman1, Jacek Lelakowski1, 2

1Department of Electrocardiology, The John Paul II Hospital, Kraków, Poland

2Institute of Cardiology, Jagiellonian University Medical College, Kraków, Poland

3John Paul II Hospital, The Adult Congenital Heart Disease Centre at the Jagiellonian University Medical College, Kraków, Poland

Correspondence to:

Krzysztof Boczar MD, PhD,

Department of Electrocardiology,

The John Paul II Hospital,

Prądnicka 80, 31–202 Kraków, Poland,

phone: + 48 12 614 22 77,

e-mail: krzysiek.boczar@gmail.com

Copyright by the Author(s), 2023

DOI: 10.33963/v.kp.98423

Received: October 20, 2023

Accepted: December 6, 2023

Early publication date: December 21, 2023

A 22-year-old female with congenital heart disease was referred to our hospital with recurrent syncope and symptoms of worsening exercise tolerance. She had been born with right ventricular hypoplasia, an atrial septal defect, and a ventricular septal defect. The patient had undergone pulmonary artery banding, hemi-Fontan operation at one year of age, and fenestrated Fontan completion two years later.

Electrocardiographic (ECG) monitoring showed episodes of sinus bradycardia with normal atrioventricular conduction (Figure 1A).

Figure 1. A. Electrocardiogram (ECG) monitoring with episodes of sinus bradycardia with normal atrioventricular conduction. B. ECG registration showing AAI pacing. C. Fluoroscopy of heart catheterization with detailed hemodynamic and angiographic evaluation of Fontan circulation. The arrow indicates fenestration between the Fontan circulation and the atrium. D. The chest radiograph after the procedure, showing the correct position of the atrial pacing lead

A spiroergometric test revealed an insufficient chronotropic response with the presence of severe dizziness, hypotension, and pre-syncope during exercise [1]. Considering the experience of our center in implanting pacemakers in patients with Fontan circulation, a collective decision was made to qualify the patient for an intravascular pacemaker [2]. Contrary to a previously described case, due to the lack of atrioventricular conduction disturbances, a plan was set to perform an intraprocedural assessment of fast atrioventricular conduction to exclude any distal conduction disturbances in the HisPurkinje system. The aim was to avoid implantation of a ventricular pacing lead, which reduces the complexity of the procedure and minimizes the risk of complications associated with the implantation of a dual-chamber pa­cing system.

Pre-procedural planning included heart catheterization with detailed hemodynamic and angiographic evaluation (Figure 1C) and ECG-gated cardiac contrast-enhanced computed tomography. Pacemaker implantation was carried out under light analgosedation in a hybrid operating room. Venous access was gained by puncture of the left subclavian vein. Fenestration in the Fontan baffle was cannulated with the Medtronic Attain Command™ delivery system (Medtronic, Minneapolis, MN, US). The lumenless Medtronic SelectSecure™ 3830 lead was placed in the right atrium via the Medtronic C315HIS Delivery Catheter. We obtained the correct sensing and pacing parameters. Atrial pacing test showed normal atrioventricular conduction up to 150 heartbeats per minute well tolerated by the patient.

The procedure and postoperative period were uneventful. A chest radiograph showed the correct position of the atrial lead (Figure 1D). Pacing parameters were excellent, and appropriate pacemaker function was confirmed on ECG monitoring (Figure 1B). Echocardiography showed no intracardiac thrombi or pericardial effusion. Treatment with warfarin was introduced for thromboembolic prevention [3]. The pacing program was set to AAIR 60/min. At the 3-month follow-up visit, the patient reported an improvement in exercise tolerance, resolution of dizziness, and pre-syncope symptoms. Echocardiography showed normal blood flow through the fenestration tunnel with no intracardiac thrombi or pericardial effusion. The spiroergometric test showed improvement in exercise tolerance, without previously observed symptoms of severe dizziness, hypotension, and pre-syncope. Pacing parameters remained within the normal range (sensing: >5.6 mV, impedance: 405 oms, and pacing threshold: 1 V/0.4 ms). The percentage of atrial pacing was 72%. There were no arrhythmic events recorded in the pacemaker’s memory.

Our moderate experience shows that transvenous pacemaker implantation can successfully and safely restore chronotropic competence in patients with hemi-Fontan circulation with subsequent fenestration. However, we still need large, prospective, and multicenter studies to objectively assess the effectiveness and safety of this pacing method in this group of patients.

Article information

Conflict of interest: None declared.

Funding: None.

Open access: This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, which allows downloading and sharing articles with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. For commercial use, please contact the journal office at kardiologiapolska@ptkardio.pl

REFERENCES

  1. Okólska M, Skubera M, Matusik P, et al. Chronotropic incompetence causes multiple organ complications in adults after the Fontan procedure. Kardiol Pol. 2021; 79(4): 410417, doi: 10.33963/KP.15853, indexed in Pubmed: 33687864.
  2. Boczar K, Ząbek A, Tomkiewicz-Pająk L, et al. Atrioventricular sequential pacemaker implantation in an adult patient with a Fontan circulation. Kardiol Pol. 2022; 80(4): 497498, doi: 10.33963/KP.a2022.0069, indexed in Pubmed: 35258093.
  3. Umamaheshwar KL, Singh AS, Sivakumar K. Endocardial transvenous pacing in patients with surgically palliated univentricular hearts: A review on different techniques, problems and management. Indian Pacing Electrophysiol J. 2019; 19(1): 1522, doi: 10.1016/j.ipej.2018.11.013, indexed in Pubmed: 30508590.