Magnetic resonance imaging in patients with cardiac implantable electronic devices in a cardio-oncology center

Mateusz Tajstra1, Maciej Dyrbuś1, Elżbieta Wojtynek2, Adam Wojtaszczyk3, Tomasz Rutkowski4, Jacek T Niedziela1, Aleksandra Błachut1, Michał Jarząb5, Sławomir Blamek6, Anna Kurek1, Jarosław Gorol1, Mateusz Witek1, Krzysztof Składowski4, Mariusz Gąsior1, Barbara Bobek-Bilewicz7
Pubmed: 36999722
Kardiol Pol 2023;81(6):619-621.

Abstract

Not available

Short communication

Magnetic resonance imaging in patients with cardiac implantable electronic devices in a cardio-oncology center

Mateusz Tajstra1Maciej Dyrbuś1Elżbieta Wojtynek2Adam Wojtaszczyk1Tomasz Rutkowski3Jacek T Niedziela1Aleksandra Błachut1Michał Jarząb4Sławomir Blamek5Anna Kurek1Jarosław Gorol1Mateusz Witek1Krzysztof Skladowski3Mariusz Gąsior1Barbara Bobek-Bilewicz6
13rd Department of Cardiology, School of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland
2Department of Cardiology and Intensive Cardiac Care Unit, Regional Specialist Hospital No. 3, Rybnik, Poland
31stDepartment of Radiation and Clinical Oncology, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
4Breast Cancer Unit, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
5Department of Radiotherapy, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland
6Department of Radiology and Imaging Diagnostic, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice Branch, Gliwice, Poland

Correspondence to:

Mateusz Tajstra, MD, PhD,

3rd Department of Cardiology, School of Medical Sciences in Zabrze,

Medical University of Silesia, Katowice,

Silesian Center for Heart Diseases,

SkłodowskiejCurie 9, 41–800 Zabrze, Poland,

phone: +48 32 373 38 60,

e-mail: mateusztajstra@wp.pl

Copyright by the Author(s), 2023

DOI: 10.33963/KP.a2023.0080

Received: December 5, 2022

Accepted: January 17, 2023

Early publication date: March 29, 2023

Introduction

Magnetic resonance imaging (MRI) has been for years contraindicated in patients with cardiac implantable electronic devices (CIEDs) due to the possibility of the occurrence of adverse events, such as acute depletion of battery voltage, changes in the lead parameters causing unsuccessful pacing or antiarrhythmic therapies, or acute device reset. However, patients with CIEDs often require diagnostics with MRI due to various causes. Despite the recommendations of scientific societies, such as the consensus document of the Heart Rhythm Society (HRS) and the recent European Society of Cardiology guidelines for cardiac pacing and cardiac resynchronization therapy, which recommend that physicians perform MRI in patients with CIEDs under specific conditions, this imaging modality is still rarely performed in patients with CIEDs, and often time from an initial assessment to MRI is prolonged, which can be critical, particularly in cancer patients, who require fast and accurate diagnostics [1, 2].

Therefore, across the globe, MRI scans in patients with CIEDs were initiated under strict surveillance of cardiac electrophysiologists according to the local prespecified protocols and in line with manufacturers’ recommendations. In 2018, in a partnership between the 3rd Department of Cardiology of the Silesian Center for Heart Diseases and Maria Skłodowska‐Curie National Research Institute of Oncology, Gliwice Branch, MRI exams in patients with various types of CIEDs were initiated [3]. This article aims to briefly summarize the characteristics of these patients as well as the immediate outcomes of the procedures.

Methods

All patients referred for MRI due to any reasons underwent a screening visit, during which the eligibility of the patients’ CIED system for MRI was assessed. In each patient, the type of device and leads were assessed, and the devices were interrogated. Both MRI-conditional and non-MRI-conditional devices were considered eligible for MRI. However, in the presence of either an epicardial, abandoned, or fractured lead, if the device was approaching elective replacement indicator, had been implanted in the previous 6 weeks, or there were any prior signs of the device malfunctions, the patient was disqualified from the procedure, pending reassessment after resolving those conditions.

On the day of the MRI scan, each patient had their device interrogated and programmed by an experienced cardiologist according to the HRS expert consensus on MRI in patients with CIEDs [1]. The programming of the device was at the discretion of the cardiologist, including the possible activation of the MRI-compatible modes. During each procedure, we continuously recorded the patient’s oximeter oxygen saturation, noninvasive blood pressure, and electrogram, and a cardiologist, an MRI technician, and a nurse were present throughout the entire MRI analysis. An external defibrillator was available on-site during every study. After completion of the MRI scan, the devices were interrogated and reprogrammed to the settings from the period before the MRI scan. The device software or hardware parameters, including variables indicating generator and lead functioning, were documented before and after MRI. Each patient was advised to undergo routine follow-up after 13 months in the patient’s local referring center. However, the physicians were obliged to instruct the patient to report for follow-up after 1 week in the patient’s local center if any of the following changes in device parameters occurred: pacing lead threshold increase by ≥1.0 V; P-wave or R-wave amplitude reductions by ≥50%; pacing lead impedance changes by ≥50 Ohm or shock lead impedance alterations by ≥5 Ohm. All scans were performed with the use of a 1.5T MRI Magnetom Aera scanner (Siemens AG, Munich, Germany).

Categorical variables were presented as absolute numbers and percentages, numerical as median with minimal and maximal values. The ethics committee’s approval and patient informed consent were not required for this study.

Results and Discussion

During the years 20182022, there were 122 patients with CIEDs, who were qualified for and underwent a total of 149 MRI studies in the presence of a cardiologist, as listed in Table 1.

Table 1. Characteristics of patients undergoing MRI under cardiologists’ surveillance during the analyzed period

Demographics

Female sex, n/n (% of all patients)

42/122 (34.4)

Age, years, median (min-max)

68 (16–90)

Region of MRI analysis

N (% of procedures)

Abdomen MRI

17 (11.4)

Brain MRI

44 (29.5)

Prostate MRI

29 (19.5)

Cardiac MRI

5 (3.6)

Spine MRI

8 (5.4)

Breast MRI

3 (2.0)

Chest MRI

3 (2.0)

Others

40 (26.8)

Type of CIED

N (% of procedures)

ICD-DR

12 (8.0)

ICD-VR

18 (12.1)

CRT

21 (14.1)

PM-DR

79 (53.0)

PM-VR

17 (11.4)

CIED manufacturers

N (% of procedures)

Medtronic/Vitatron

81 (54.4)

Biotronik

26 (17.4)

Boston Scientific

18 (12.1)

St. Jude/Abbott

24 (16.1)

Device characteristics

N (% of procedures)

Pacing dependency

34 (22.8)

Secondary prevention of SCD, of all ICD/CRT-D devices

6 (12.0)

MRI-conditional device

60 (40.3)

The majority of patients underwent either MRI of the brain (29.5%) or the abdominal/pelvic region (30.9% in aggregate). The most common type of CIED was a double-chamber pacemaker (52.3%), and the majority of the devices were Medtronic/Vitatron devices (54.4%). Notably, there was 1 patient with an implanted loop recorder and one patient with subcutaneous implantable cardioverter-defibrillator (ICD) who underwent an MRI scan. None of the procedures were associated with any programming alterations. Moreover, no immediate changes in either battery voltage, pacing threshold, or sensing were observed. In three patients, a change in high-voltage lead impedance by 5 Ohms, 6 Ohms, and 8 Ohms was observed, without any other alterations in device parameters.

The number of patients with malignancy and concomitant heart failure, or any other cardiac disease requiring the implantation of CIEDs grows each year. The prior calculations estimated that approximately 50%–75% of patients with a CIED could need an MRI scan in the lifetime of the device, which could potentially increase even further with constantly prolonged device longevity and wider adoption of MRI into diagnostic processes [4]. Nonetheless, in some MRI-equipped facilities, the presence of CIEDs is still considered a contraindication to performing MRI. Therefore, it is crucial to demonstrate that in the real-world setting, patients with CIEDs may undergo a safe MRI scan, which is often the most important diagnostic modality in the course of their disease.

In order to facilitate easier access to MRI, the device manufacturers have introduced MRI-conditional devices, whose structure and design reduce the risk of system overheating or any other form of electromagnetic interference [5, 6]. Nonetheless, it should be noted that these devices are not completely prone to dysfunction during MR [7], and the presence of dedicated personnel, conversant with CIED programming is still recommended during the MRI scan. The 2021 European Society of Cardiology guidelines for cardiac pacing and cardiac resynchronization therapy recommend performing MRI in MRI-conditional devices provided that the manufacturers’ guidelines are followed, while in the non-MRI-conditional devices, the examination should be recommended if no other alternative imaging methods are available and there are no epicardial, abandoned, or dysfunctional leads [2]. Similarly, the 2017 HRS Consensus on MRI and radiation therapy in patients with CIEDs recommends a rigorous structured approach in patients with both MRI-conditional and non-MRI-conditional devices [1].

Previously published data from other facilities are in line with our results. In a large, retrospective analysis of more than 2100 MRI scans performed in patients with non-MRI-conditional devices, in only nine devices power-on resets were identified [8]. In another multicenter registry of non-MRI-conditional devices in patients who underwent nonthoracic MRI, in 1500 scans performed, no hardware failures were identified as far as a generator or lead were concerned if the device was programmed according to the prespecified protocol [9]. However, the cited evidence included also a long-term follow-up of the devices, which was not available in our analysis. Thus, it should be considered as a limitation of our study. Our results, as well as the cited literature, indicate that a structured, rigorously planned, and implemented MRI strategy under the surveillance of a cardiologist experienced in the interrogation and management of CIEDs enables a safe procedure, enhances the availability of imaging diagnostics in patients requiring MRI, in whom the scan is often crucial for diagnosis and monitoring of their diseases.

Article information

Conflict of interest: None declared.

Funding: None.

Open access: This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, which allows downloading and sharing articles with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. For commercial use, please contact the journal office at kardiologiapolska@ptkardio.pl.

REFERENCES

  1. Indik JH, Gimbel JR, Abe H, et al. 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm. 2017; 14(7): e97e9e153, doi: 10.1016/j.hrthm.2017.04.025, indexed in Pubmed: 28502708.
  2. Glikson M, Nielsen JC, Kronborg MB, et al. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Europace. 2022; 24(1): 71164, doi: 10.1093/europace/euab232, indexed in Pubmed: 34455427.
  3. Tajstra M, Blamek S, Skoczylas I, et al. Two professions against two killer diseases: the rationale, organization, and initial experience of a cardio-oncology service. Kardiol Pol. 2021; 79(2): 139146, doi: 10.33963/KP.15674, indexed in Pubmed: 33146505.
  4. Kalin R, Stanton MS. Current clinical issues for MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol. 2005; 28(4): 326328, doi: 10.1111/j.1540-8159.2005.50024.x, indexed in Pubmed: 15826268.
  5. Wilkoff BL, Bello D, Taborsky M, et al. Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm. 2011; 8(1): 6573, doi: 10.1016/j.hrthm.2010.10.002, indexed in Pubmed: 20933098.
  6. Gimbel JR, Bello D, Schmitt M, et al. Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla. Heart Rythm. 2013; 10(5): 685691, doi: 10.1016/j.hrthm.2013.01.022, indexed in Pubmed: 23333721.
  7. Krebsbach A, Dewland TA, Henrikson CA. Malfunction of an MRI-Conditional Pacemaker Following an MRI. HeartRhythm Case Rep. 2017; 3(2): 148150, doi: 10.1016/j.hrcr.2016.11.007, indexed in Pubmed: 28491791.
  8. Nazarian S, Hansford R, Rahsepar AA, et al. Safety of magnetic resonance imaging in patients with cardiac devices. N Engl J Med. 2017; 377(26): 25552564, doi: 10.1056/NEJMoa1604267, indexed in Pubmed: 29281579.
  9. Russo RJ, Costa HS, Silva PD, et al. Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator. N Engl J Med. 2017; 376(8): 755764, doi: 10.1056/NEJMoa1603265, indexed in Pubmed: 28225684.