CLINICAL VIGNETTE

Upgrade to cardiac resynchronization therapy with robotic-assisted implantation of the left ventricular lead: Case report

Mateusz TajstraMaciej DyrbuśMateusz OstręgaKrzysztof DyrbuśMariusz Gąsior
3rd Department of Cardiology, School of Medical Sciences in Zabrze, Medical University of Silesia, Katowice, Poland

Correspondence to:

Maciej Dyrbuś, MD, PhD,

3rd Department of Cardiology,

School of Medical Sciences in Zabrze,

Medical University of Silesia,

Skłodowskiej-Curie 9, 04–628 Zabrze, Poland,

phone: +48 32 343 46 46,

e-mail: mdyrbus@op.pl

Copyright by the Author(s), 2024

DOI: 10.33963/v.phj.100350

Received: March 9, 2024

Accepted: April 22, 2024

Early publication date: April 22, 2024

Cardiac resynchronization therapy is the cornerstone of modern electrotherapy [1, 2]; however, in some cases, implantation of the left ventricular lead into the cardiac venous system can be challenging, and the utmost precision is needed to optimally cannulate the targeted vein with a guidewire. In recent years, growing interest has been placed on robo­tic-assisted percutaneous coronary interventions, which allow maximizing the operator’s manual accuracy, while potentially reducing fluoroscopy time and radiation exposure to both the operator and the patient [3]. However, to date, there have been no reports on robotic-assisted cardiac implantable electronic device implantation. Thus, we pre­sent the first case of a successful robotic-assisted implantation of the left ventricular lead.

A 63-year-old female patient, with a dual-chamber pacemaker implanted one year earlier due to symptomatic sinus node dysfunction, was admitted to the hospital on account of exercise intolerance and fatigue. Device interrogation showed double chamber pacing with closed loop stimulation 60/min programming, with 55% ventricular pacing despite algorithms prolonging atrioventricular (AV) delay. On the electrocardiogram, sinus rhythm with periodical atrial pacing was observed, along with first-degree AV block (PR of 280 ms) and left bundle branch block, with a native QRS width of 155 ms. On echocardiography, left ventricular ejection fraction was 37%, with evident interventricular dyssynchrony.

Considering the overall clinical status of the patient, we decided to upgrade cardiac resynchronization therapy with robotic-assisted implantation of the left ventricular lead. During the procedure, the coronary sinus was cannulated, and two small posterior veins were observed on venography. However, their angulation immediately after the ostia was very unfavorable for successful cannulation. Nonetheless, the middle cardiac vein gave rise to many large tributaries eventually leading to the postero-lateral wall of the left ventricle. A decision was made to attempt the implantation of the LV lead into one of the posterior veins, and if unsuccessful, the middle cardiac vein was selected as the second choice. Due to the anticipated potential difficulties in approaching the destination veins, a decision was made to utilize the R-One+ robotic assistance platform (Robocath, France) [4].

The over-the-wire 300 cm balance middleweight 0.014” guidewire was advanced using the widely available vascular extension line connected to the coronary sinus guide catheter. A few attempts to cannulate the posterior veins were unsuccessful and, eventually, the wire was successfully placed in the tributary of the middle cardiac vein, which supplied the postero-lateral LV wall. The left ventricular lead was then implanted into the destination vein with satisfactory sensing and pacing parameters and no signs of phrenic nerve stimulation. The consecutive steps of the procedure are summarized in Figure 1 and Supplementary material, Video S1. The patient was discharged the next day, without complications.

Figure 1: Robotic-assisted left ventricular lead implantation. A. View of the 300 cm balance middleweight 0.014” guidewire (red arrow) being introduced into the coronary sinus catheter (black arrow) using a dedicated advancement set. B. The R-One+ robotic assistance platform (Robocath, France), installed and connected with the coronary sinus catheter using the vascular extension line (white asterisk) via the system’s dedicated Y-connector (red asterisk). C. The operator in the control room manipulating the guidewire. D. Coronary sinus venography demonstrating relatively scarce tributaries to the coronary sinus and the great cardiac vein (blue arrows) and a large middle cardiac vein (yellow arrow). E. Final position of the left ventricular lead implanted in the postero-lateral wall of the left ventricle. F. The patient’s electrocardiogram after the procedure showing LV capture in lead V1 and a QRS duration of 152 ms

One of the major benefits of robotic-assisted guidewire manipulation is increased precision, as the system allows the operator to carefully move and rotate the guidewire, thus enabling successful cannulation of a wider spectrum of tributaries. Robotic-assisted percutaneous procedures will undoubtedly see rapid development in the coming years, with left ventricular lead placement as an interesting option for using this technology in patients requiring cardiac resynchronization therapy.

Supplementary material

Supplementary material is available at https://journals.viamedica.pl/polish_heart_journal.

Article information

Conflict of interest: None declared.

Funding: None.

Open access: This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, which allows downloading and sharing articles with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. For commercial use, please contact the journal office at polishheartjournal@ptkardio.pl

REFERENCES

  1. Linde C. Cardiac resynchronization in heart failure: Recent advances and their practical implications. Kardiol Pol. 2023; 81(1): 713, doi: 10.33963/KP.a2023.0020, indexed in Pubmed: 36744912.
  2. Grymuza M, Katarzyńska-Szymańska A, Chmielewska-Michalak L, et al. Follow-up and characteristics of recipients of cardiac resynchronization therapy with and without a defibrillator. Kardiol Pol. 2022; 80(7-8): 806812, doi: 10.33963/KP.a2022.0125, indexed in Pubmed: 35545837.
  3. Koulaouzidis G, Charisopoulou D, Bomba P, et al. Robotic-assisted solutions for invasive cardiology, cardiac surgery and routine on-ward tasks: A narrative review. J Cardiovasc Dev Dis. 2023; 10(9): 399, doi: 10.3390/jcdd10090399, indexed in Pubmed: 37754828.
  4. Durand E, Sabatier R, Smits PC, et al. Evaluation of the R-One robotic system for percutaneous coronary intervention: the R-EVOLUTION study. EuroIntervention. 2023; 18(16): e1339e1347, doi: 10.4244/EIJ-D-22-00642, indexed in Pubmed: 36602883.