Percutaneous valve implantation in the pulmonary position is a well-established treatment for right ventricular outflow tract (RVOT) dysfunction [1]. Improvements in valve design have provided new options for percutaneous treatment of large outflow tracts [2, 3]. Our recent experience demonstrates successful self-expanding valve implantation in pediatric patients via the standard femoral vein (FV) approach [4]. However, in selected patients, alternative vascular access may be necessary [5].
A 16-year-old male patient weighing 45 kg with tetralogy of Fallot, following previous correction with a transannular patch, was referred to our Department due to worsening exercise tolerance. Echocardiography and computed tomography scans revealed a significantly enlarged right ventricle and a dilated RVOT with severe pulmonary regurgitation.
During cardiac catheterization, contrast injection into the right FV demonstrated occlusion of the ipsilateral iliac vein with collateral vessels (Supplementary material, Figure S1A, Video S1). Angiography from the left FV showed a significantly narrowed iliac vein with collateral vessels (Supplementary material, Figure S1B). Given limited FV access, a decision was made to attempt valve implantation via the right internal jugular vein (RIJV). Access to the left FV was used to introduce a 5 Fr sheath and a diagnostic catheter for the initial angiography (Supplementary material, Figure S1C) and intra-procedural angiographic guidance. A compliant sizing balloon was inflated in the RVOT for measurements (Supplementary material, Figure S1D–E) and evaluation of potential coronary compression. Flattening of the right coronary sinus, without causing aortic regurgitation, was noticed (Supplementary material, Figure S1F). Considering measurements on the initial angiography and the inflated balloon, a 36–25 mm Venus-P valve (Venus MedTech) was selected for implantation from the RIJV. Over a 0.035” Lunderquist guidewire (Cook) anchored in the distal branch of the right pulmonary artery, a 26Fr DrySeal sheath (Gore) was introduced from the RIJV to the proximal right pulmonary artery (Figure 1A). The valve was gradually exposed to allow the distal flare to sit in the distal main pulmonary artery and slowly deployed fully (Figure 1B–C). The final angiography confirmed satisfactory valve position and function, with unobstructed pulmonary artery flow, trace pulmonary regurgitation, and no coronary artery compression (Figure 1D–E). Pre-discharge and 6-month follow-up echocardiograms showed good valve function with trivial central pulmonary regurgitation. No arrhythmias were detected on follow-up routine electrocardiograms.
The transjugular approach for balloon-expanding valves has several applications including when there is no femoral venous access or interrupted inferior vena cava [5]. There are limited data on the utilization of this route for the implantation of self-expanding valves, especially in smaller patients. One of the crucial parts of the procedure is to accurately puncture the jugular vein, using ultrasound guidance. Subsequent introduction of a large delivery sheath and the valve is similar to when valve implantation is performed via the usual femoral route. No hemodynamic compromise or arrhythmia was encountered with slow introduction of the large-caliber equipment. The course of the sheath in the right ventricle gave stable support during exposure of the valve leading to the accurate final position. Therefore, consideration should be given to using this approach in patients with limited femoral venous access.
Supplementary material
Supplementary material is available at https://journals.viamedica.pl/polish_heart_journal.
Article information
Acknowledgments: To Anna Grondalski from Pomeranian Medical University for editing the text.
Conflict of interest: RB is an employee of Venus MedTech. Other authors declared no conflict of interest.
Funding: None.
Open access: This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, which allows downloading and sharing articles with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. For commercial use, please contact the journal office at polishheartjournal@ptkardio.pl