Findings in [99mTc]MAA SPECT/CT in the diagnosis and follow-up of pulmonary embolism after infection by SARS-CoV-2 (COVID-19)

Marylin Acuña Hernandez1, Tatiana Morales Avellaneda12, Jorge Andres Narvaez Gomez1, Liset Sanchez Orduz2
·
Pubmed: 34382682
·
Nucl. Med. Rev 2021;24(2):120-121.
Affiliations
  1. Universidad AutóNoma De Bucaramanga, Santander, Colombia
  2. Spect Medicina Nuclear S.A.S, Centro medico carlos ardila Lulle, Bucaramanga, Colombia

open access

Vol 24, No 2 (2021)
Clinical vignette
Submitted: 2021-03-05
Accepted: 2021-03-15
Published online: 2021-07-30

Abstract

SARS-CoV-2 (COVID-19) infection is a current public health problem that has been shown to cause multiple complications, including pulmonary thromboembolism. The first presented case is a 59-year-old woman with a history of COPD, paroxysmal atrial fibrillation and COVID-19 infection in September 2020, consultation in December 2020 for atypical chest pain with suspected PE, AngioCT of pulmonary vessels was performed negative for emboli, subsequently [99mTc]Tc MAA SPECT/CT was indicated with a report of multiple triangular defects concerning acute pulmonary thromboembolism. A second case is a 70-year-old man with a history of dyslipidaemia, presented COVID-19 infection in September 2020 with a complication of PE with involvement of the left pulmonary artery, followed by [99mTc]Tc MAA SPECT/CT report multiple triangular and not triangles defects concerning pulmonary thromboembolism with signs of reperfusion.

Abstract

SARS-CoV-2 (COVID-19) infection is a current public health problem that has been shown to cause multiple complications, including pulmonary thromboembolism. The first presented case is a 59-year-old woman with a history of COPD, paroxysmal atrial fibrillation and COVID-19 infection in September 2020, consultation in December 2020 for atypical chest pain with suspected PE, AngioCT of pulmonary vessels was performed negative for emboli, subsequently [99mTc]Tc MAA SPECT/CT was indicated with a report of multiple triangular defects concerning acute pulmonary thromboembolism. A second case is a 70-year-old man with a history of dyslipidaemia, presented COVID-19 infection in September 2020 with a complication of PE with involvement of the left pulmonary artery, followed by [99mTc]Tc MAA SPECT/CT report multiple triangular and not triangles defects concerning pulmonary thromboembolism with signs of reperfusion.

Get Citation

Keywords

pulmonary embolism; coronavirus infections; ventilation-perfusion scan; diagnosis

About this article
Title

Findings in [99mTc]MAA SPECT/CT in the diagnosis and follow-up of pulmonary embolism after infection by SARS-CoV-2 (COVID-19)

Journal

Nuclear Medicine Review

Issue

Vol 24, No 2 (2021)

Article type

Clinical vignette

Pages

120-121

Published online

2021-07-30

Page views

6834

Article views/downloads

642

DOI

10.5603/NMR.2021.0029

Pubmed

34382682

Bibliographic record

Nucl. Med. Rev 2021;24(2):120-121.

Keywords

pulmonary embolism
coronavirus infections
ventilation-perfusion scan
diagnosis

Authors

Marylin Acuña Hernandez
Tatiana Morales Avellaneda
Jorge Andres Narvaez Gomez
Liset Sanchez Orduz

References (3)
  1. Lu Y, Macapinlac HA. Perfusion SPECT/CT to diagnose pulmonary embolism during COVID-19 pandemic. Eur J Nucl Med Mol Imaging. 2020; 47(9): 2064–2065.
  2. Sakr Y, Giovini M, Leone M, et al. Pulmonary embolism in patients with coronavirus disease-2019 (COVID-19) pneumonia: a narrative review. Ann Intensive Care. 2020; 10(1): 124.
  3. Cavagna E, Muratore F, Ferrari F. Pulmonary Thromboembolism in COVID-19: Venous Thromboembolism or Arterial Thrombosis? Radiol Cardiothorac Imaging. 2020; 2(4): e200289.

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., Świętokrzyska 73 street, 80–180 Gdańsk, Poland

phone: +48 58 320 94 94, fax: +48 58 320 94 60, e-mail: viamedica@viamedica.pl