open access

Vol 67, No 5 (2017)
Irradiation techniques
Published online: 2018-02-22
Get Citation

Dynamic-arc respiratory-gated stereotactic radiotherapy — technique presentation

Grzegorz Woźniak, Łukasz Dolla, Krzysztof Ślosarek, Barbara Bekman, Tomasz Latusek, Grzegorz Głowacki
·
Nowotwory. Journal of Oncology 2017;67(5):297-300.

open access

Vol 67, No 5 (2017)
Irradiation techniques
Published online: 2018-02-22

Abstract

Main advancements in radiation treatment in recent years have included the introduction of dynamic techniques and 4D radiotherapy. The treatment of movable tumors relies on two important techniques: gating and tracking. The limitation of the former is the relatively short duration of the respiratory phase during which the radiation can be delivered and the need to teach the patient to breathe in accordance with the correct pattern. At the same time, certain clinical situations require the use of dynamic techniques. Intensity modulated radiotherapy (IMRT), combined with gantry rotation, forms the basis for the VMAT technique. The procedure usually takes a shorter time to complete than other dynamic techniques, which considerably improves patient comfort. The recently introduced True BeamTM accelerator employs all the latest innovations in terms of dose-rate modeling and respiratory gating.

Abstract

Main advancements in radiation treatment in recent years have included the introduction of dynamic techniques and 4D radiotherapy. The treatment of movable tumors relies on two important techniques: gating and tracking. The limitation of the former is the relatively short duration of the respiratory phase during which the radiation can be delivered and the need to teach the patient to breathe in accordance with the correct pattern. At the same time, certain clinical situations require the use of dynamic techniques. Intensity modulated radiotherapy (IMRT), combined with gantry rotation, forms the basis for the VMAT technique. The procedure usually takes a shorter time to complete than other dynamic techniques, which considerably improves patient comfort. The recently introduced True BeamTM accelerator employs all the latest innovations in terms of dose-rate modeling and respiratory gating.

Get Citation

Keywords

respiratory gating, stereotactic radiotherapy, dynamic arc, VMAT

About this article
Title

Dynamic-arc respiratory-gated stereotactic radiotherapy — technique presentation

Journal

Nowotwory. Journal of Oncology

Issue

Vol 67, No 5 (2017)

Pages

297-300

Published online

2018-02-22

Page views

888

Article views/downloads

823

DOI

10.5603/NJO.2017.0049

Bibliographic record

Nowotwory. Journal of Oncology 2017;67(5):297-300.

Keywords

respiratory gating
stereotactic radiotherapy
dynamic arc
VMAT

Authors

Grzegorz Woźniak
Łukasz Dolla
Krzysztof Ślosarek
Barbara Bekman
Tomasz Latusek
Grzegorz Głowacki

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

Wydawcą serwisu jest VM Media Group sp. z o.o., ul. Świętokrzyska 73, 80–180 Gdańsk

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail: viamedica@viamedica.pl