The clinical significance of electronic fetal heart rate monitoring in twins


- Department of Perinatology and Gynecology, Poznan University of Medical Sciences, Poznan, Poland
- Department of Computer Science and Statistics, Poznan University of Medical Sciences, Poznan, Poland
- Department of General and Colorectal Surgery, Poznan University of Medical Sciences, Poznan, Poland
open access
Abstract
Objectives: Fully effective intrapartum cardiotocographic (CTG) fetal heart monitoring is still missing. Visual analysis is far from credibility. Additional, computerized analysis techniques were proposed however they did not substantially decrease possible risks of fetal asphyxia. In twin pregnancies the problem is even more complicated. Our goal is to find the most valuable parameters in intrapartum CTG surveillance in twins, based on actual FIGO criteria.
Material and methods: Study included 58 women in labor who had been admitted to Delivery Department of tertiary care hospital with twin pregnancy in a period of one year. The features of the CTG (e.g., baseline, oscillation, decelerations, brady- or tachycardia) were grouped to create three variables that were closest to the FIGO CTG scale. All three groups were compared according to neonatal status (Apgar score at 5 min ≥ 7 or < 7; pH value in umbilical artery ≥ 7.20, < 7.20 or < 7.10 and BE (base excess) > or ≤ –12). Fetal status and its acid — base equilibrium was compared either with long term variability (LTV), short term variability (STV), or percentage of the signal loss.
Results: Out of 58 twin pregnancies, a total of 116 babies were born. One baby was born dead. From this group, 11 deliveries were natural births and 47 deliveries were C-sections. None of the analyzed features (pH, BE, Apgar, CTG features except tracing length, CTG FIGO categories) were statistically different between groups of singleton and twin pregnancies, except percentage of C-sections. No differences were found either for STV or LTV and fetal status.org CTG categories.
Conclusions: Prior to cardiotocographic tracing of twins during labor, ultrasound examination should be mandatory. Considerable loss of signal in CTG tracing in twins should provoke ultrasonographic confirmation of the fetal status.
Abstract
Objectives: Fully effective intrapartum cardiotocographic (CTG) fetal heart monitoring is still missing. Visual analysis is far from credibility. Additional, computerized analysis techniques were proposed however they did not substantially decrease possible risks of fetal asphyxia. In twin pregnancies the problem is even more complicated. Our goal is to find the most valuable parameters in intrapartum CTG surveillance in twins, based on actual FIGO criteria.
Material and methods: Study included 58 women in labor who had been admitted to Delivery Department of tertiary care hospital with twin pregnancy in a period of one year. The features of the CTG (e.g., baseline, oscillation, decelerations, brady- or tachycardia) were grouped to create three variables that were closest to the FIGO CTG scale. All three groups were compared according to neonatal status (Apgar score at 5 min ≥ 7 or < 7; pH value in umbilical artery ≥ 7.20, < 7.20 or < 7.10 and BE (base excess) > or ≤ –12). Fetal status and its acid — base equilibrium was compared either with long term variability (LTV), short term variability (STV), or percentage of the signal loss.
Results: Out of 58 twin pregnancies, a total of 116 babies were born. One baby was born dead. From this group, 11 deliveries were natural births and 47 deliveries were C-sections. None of the analyzed features (pH, BE, Apgar, CTG features except tracing length, CTG FIGO categories) were statistically different between groups of singleton and twin pregnancies, except percentage of C-sections. No differences were found either for STV or LTV and fetal status.org CTG categories.
Conclusions: Prior to cardiotocographic tracing of twins during labor, ultrasound examination should be mandatory. Considerable loss of signal in CTG tracing in twins should provoke ultrasonographic confirmation of the fetal status.
Keywords
fetal heart; twin pregnancy; monitoring; cardiotocography


Title
The clinical significance of electronic fetal heart rate monitoring in twins
Journal
Issue
Article type
Research paper
Pages
839-844
Published online
2022-10-27
Page views
440
Article views/downloads
323
DOI
Pubmed
Bibliographic record
Ginekol Pol 2023;94(10):839-844.
Keywords
fetal heart
twin pregnancy
monitoring
cardiotocography
Authors
Anna Dera-Szymanowska
Martyna Polska
Wieslaw Markwitz
Jerzy Moczko
Nikodem Horst
Krzysztof Szymanowski


- Redman C, Stanger D, Albert B. Computerised analysis of the antepartum cardiotocogram (CTG) for care of the compromised fetus. Pregnancy Hypertension. 2017; 7: 58.
- Obstetric care consensus no. 1: safe prevention of the primary cesarean delivery. Obstet Gynecol. 2014; 123(3): 693–711.
- Spencer JA, Badawi N, Burton P, et al. The intrapartum CTG prior to neonatal encephalopathy at term: a case-control study. Br J Obstet Gynaecol. 1997; 104(1): 25–28.
- Schiermeier S, Steinburg SP, Thieme A, et al. Sensitivity and specificity of intrapartum computerised FIGO criteria for cardiotocography and fetal scalp pH during labour: multicentre, observational study. BJOG. 2008; 115(12): 1557–1563.
- Agrawal S, Doucette F, Gratton R, et al. Intrapartum computerized fetal heart rate parameters and metabolic acidosis at birth. Obstet Gynecol. 2003; 102(4): 731–738.
- Tuzel J. Assessment of the relation between fetal heart rate variability during labour with the perinatal status of neonate. Doctor dissertation. Medical University, Poznan 2018: Poland.
- Ayres-de-Campos D, Spong CY, Chandraharan E, et al. FIGO Intrapartum Fetal Monitoring Expert Consensus Panel. FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography. Int J Gynaecol Obstet. 2015; 131(1): 13–24.
- INFANT Collaborative Group. Computerised interpretation of fetal heart rate during labour (INFANT): a randomized controlled trial. Lancet. 2017; 389(10080): 1719–1729.
- Annunziata ML, Tagliaferri S, Esposito FG, et al. Computerized analysis of fetal heart rate variability signal during the stages of labor. J Obstet Gynaecol Res. 2016; 42(3): 258–265.
- Keith RDF, Greene KR. Development, evaluation and validation of an intelligent decision support tool for the management of labour. In: Chang AMZ, RogersMS, eds. Analysis of complex data in obstetrics. Baillieres Clin Obstet Gynaecol. 1994; 8(3): 583–605.
- The INFANT collaborative group. Computerised interpretation of fetal heart rate during labour (INFANT): a randomized controlled trial. Lancet. 2017; 389(10080): 1719–1729.
- Anceschi MM, Ruozi-Berretta A, Piazze JJ, et al. Computerized cardiotocography in the management of intrauterine growth restriction associated with Doppler velocimetry alterations. Int J Gynaecol Obstet. 2004; 86(3): 365–370.
- Strachan B, van Wijngaarden WJ, Sahota D, et al. Cardiotocography only versus cardiotocography plus PR-interval analysis in intrapartum surveillance: a randomised, multicentre trial. Lancet. 2000; 355(9202): 456–459.
- Amorim-Costa C, Costa-Santos C, Ayres-de-Campos D, et al. Longitudinal evaluation of computerized cardiotocographic parameters throughout pregnancy in normal fetuses: a prospective cohort study. Acta Obstet Gynecol Scand. 2016; 95(10): 1143–1152.
- Schiermeier S, Reinhard J, Hatzmann H, et al. Fetal short time variation during labor: a non-invasive alternative to fetal scalp pH measurements? J Perinat Med. 2009; 37(5): 529–533.
- Słomko Z, Drews K, Malewski Z. Kardiotokografia kliniczna. PZWL, Warszawa 2010: 285.