Measurement of tumor markers level in human body fluids, mainly in serum may be useful for diagnosis, therapy monitoring and early recurrence detection. SCC-Ag, Cyfra 21-1, CEA, CA 125 and TPS are of a clinical value in uterine cervical cancer despite their diverse significance. Other biological markers that could be measured in serum as well as in tumor tissue are cytokines: VEGF, IL-6, IL-8, IL-4, IL-10, leptin, stromal drive factor (SDF-1), although assessment of their importance needs further examination. Elevation of uterine cervical cancer hypoxia markers such as HIF 1a, CA 9, GLUT- 1 is combined with poorer clinical outcome prognosis.

Abstract

Measurement of tumor markers level in human body fluids, mainly in serum may be useful for diagnosis, therapy monitoring and early recurrence detection. SCC-Ag, Cyfra 21-1, CEA, CA 125 and TPS are of a clinical value in uterine cervical cancer despite their diverse significance. Other biological markers that could be measured in serum as well as in tumor tissue are cytokines: VEGF, IL-6, IL-8, IL-4, IL-10, leptin, stromal drive factor (SDF-1), although assessment of their importance needs further examination. Elevation of uterine cervical cancer hypoxia markers such as HIF 1a, CA 9, GLUT- 1 is combined with poorer clinical outcome prognosis.
Get Citation

Keywords

tantigenes neoplasms - analysis, tumor markers biological - analysis, tumor markers biological - blood, uterine cervical neoplasms

About this article
Title

Tumor makers in cervical cancer

Journal

Ginekologia Polska

Issue

Vol 78, No 9 (2007)

Page views

568

Article views/downloads

6774

Bibliographic record

Ginekol Pol 2007;78(9).

Keywords

tantigenes neoplasms - analysis
tumor markers biological - analysis
tumor markers biological - blood
uterine cervical neoplasms

Authors

Janina Markowska

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., ul. Świętokrzyska 73, 80–180 Gdańsk
tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail:  viamedica@viamedica.pl