open access

Vol 80, No 1 (2009)
ARTICLES
Get Citation

The assessment of neutrophil elastase measurements usefulness in pregnant women with premature rupture of fetal membranes and chorioamnionitis suspicion

Rafał Rzepka, Andrzej Torbe, Barbara Dołęgowska, Dariusz Chludek, Sebastian Kwiatkowski, Ryszard Czajka
Ginekol Pol 2009;80(1).

open access

Vol 80, No 1 (2009)
ARTICLES

Abstract

Summary Objectives: The evaluation of neutrophil elastase (NE) levels and its usefulness in pregnant women with premature rupture of foetal membranes (PROM) and chorioamnionitis suspicion. Material and methods: We evaluated the relationship between maternal plasma and amniotic fluid NE levels with the presence of chorioamnion infection in sixty pregnant women, divided into two groups – with and without PROM. The diagnostic performance of NE evaluations in discrimination of suspected intraamniotic infection was calculated. Results: NE levels in PROM patients are significantly higher than in the control group (p <0.000001). Significantly higher NE concentrations are also observed in the case of chorioamnionitis. Moreover, if at least two clinical markers of infection were present, the diagnostic value of amniotic fluid NE levels proved to be 100% sensitive and of 100% negative predictive value. Conclusions: NE levels may be used as clinical markers which enable the obstetricians to exclude chorioamnionitis.

Abstract

Summary Objectives: The evaluation of neutrophil elastase (NE) levels and its usefulness in pregnant women with premature rupture of foetal membranes (PROM) and chorioamnionitis suspicion. Material and methods: We evaluated the relationship between maternal plasma and amniotic fluid NE levels with the presence of chorioamnion infection in sixty pregnant women, divided into two groups – with and without PROM. The diagnostic performance of NE evaluations in discrimination of suspected intraamniotic infection was calculated. Results: NE levels in PROM patients are significantly higher than in the control group (p <0.000001). Significantly higher NE concentrations are also observed in the case of chorioamnionitis. Moreover, if at least two clinical markers of infection were present, the diagnostic value of amniotic fluid NE levels proved to be 100% sensitive and of 100% negative predictive value. Conclusions: NE levels may be used as clinical markers which enable the obstetricians to exclude chorioamnionitis.
Get Citation

Keywords

neutrophil elastase, preterm premature rupture of fetal membranes, Chorioamnionitis

About this article
Title

The assessment of neutrophil elastase measurements usefulness in pregnant women with premature rupture of fetal membranes and chorioamnionitis suspicion

Journal

Ginekologia Polska

Issue

Vol 80, No 1 (2009)

Page views

556

Article views/downloads

783

Bibliographic record

Ginekol Pol 2009;80(1).

Keywords

neutrophil elastase
preterm premature rupture of fetal membranes
Chorioamnionitis

Authors

Rafał Rzepka
Andrzej Torbe
Barbara Dołęgowska
Dariusz Chludek
Sebastian Kwiatkowski
Ryszard Czajka

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., ul. Świętokrzyska 73, 80–180 Gdańsk
tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail:  viamedica@viamedica.pl