open access
Normative size evaluation of IAC with MRI: Review of 3786 patients
open access
Abstract
Material and methods: A retrospective review was undertaken from 2010 to 2012. A total of 7572 normal-hearing ears of 3786 patients were assessed, who had MRI due to various reasons except hearing loss. Patients under 20 years old and over 60 years old were excluded, and the subjects were divided into 4 groups at 10-year intervals. All subjects were divided by gender also. Anteroposterior (AP) and craniocaudal (CC) measurements were obtained in the middle of the IAC on axial and coronal images of 1.5-T MRI.
Results: The mean age was 42 years (range 20–60 years). The mean IAC diameters were 5.93 mm with a standard deviation of 0.25 mm (max 6.99 mm, min 4.73 mm) on AP measurements and were 5.70 mm with a standard deviation of 0.26 mm (max 6.82 mm, min 4.71 mm) on CC measurements. There were no differences in the IAC diameters between males and females or with age groups.
Conclusions: These measurements should provide a normative reference for comparison in radiographic assessment of any patient with suspected IAC stenosis. This measurement can help the diagnosis of narrow IAC. To our knowledge, this is the first study using MRI with a large group of patients in the literature.
Abstract
Material and methods: A retrospective review was undertaken from 2010 to 2012. A total of 7572 normal-hearing ears of 3786 patients were assessed, who had MRI due to various reasons except hearing loss. Patients under 20 years old and over 60 years old were excluded, and the subjects were divided into 4 groups at 10-year intervals. All subjects were divided by gender also. Anteroposterior (AP) and craniocaudal (CC) measurements were obtained in the middle of the IAC on axial and coronal images of 1.5-T MRI.
Results: The mean age was 42 years (range 20–60 years). The mean IAC diameters were 5.93 mm with a standard deviation of 0.25 mm (max 6.99 mm, min 4.73 mm) on AP measurements and were 5.70 mm with a standard deviation of 0.26 mm (max 6.82 mm, min 4.71 mm) on CC measurements. There were no differences in the IAC diameters between males and females or with age groups.
Conclusions: These measurements should provide a normative reference for comparison in radiographic assessment of any patient with suspected IAC stenosis. This measurement can help the diagnosis of narrow IAC. To our knowledge, this is the first study using MRI with a large group of patients in the literature.
Keywords
internal auditory canal; magnetic resonance imaging
Title
Normative size evaluation of IAC with MRI: Review of 3786 patients
Journal
Issue
Article type
Original article
Pages
217-220
Published online
2012-11-30
Page views
1632
Article views/downloads
6203
Bibliographic record
Folia Morphol 2012;71(4):217-220.
Keywords
internal auditory canal
magnetic resonance imaging
Authors
M. Fatih Erkoç
H. Imamoglu
A. Okur
C. Gumus
M. Dogan