Vol 29, No 2 (2022)
Image in Cardiovascular Medicine
Published online: 2022-04-07

open access

Page views 5154
Article views/downloads 536
Get Citation

Connect on Social Media

Connect on Social Media

Balloon-assisted tracking deployment of a coronary sinus reducer through a Vieussens valve

Fernando Rivero1, Javier Cuesta1, Santiago Jiménez-Valero2, Teresa Bastante1, David del Val1, Fernando Alfonso1
Pubmed: 35411932
Cardiol J 2022;29(2):360-361.

Abstract

Not available

interventionAL CARDIOLOGY

IMAGE IN CARDIOVASCULAR MEDICINE

Cardiology Journal 2022, Vol. 29, No. 2, 360–361

DOI: 10.5603/CJ.2022.0017

Copyright © 2022 Via Medica

ISSN 1897–5593 eISSN 1898018X

Balloon-assisted tracking deployment of a coronary sinus reducer through a Vieussens valve

199529.png
Fernando Rivero1Javier Cuesta1Santiago Jiménez-Valero2Teresa Bastante1David del Val1Fernando Alfonso1
1Department of Cardiology, Hospital Universitario de La Princesa, Instituto de Investigación Sanitaria, IIS-IP, CIBER-CV, Spain
2Department of Cardiology, La Paz University Hospital, Madrid, Spain

Address for correspondence: Fernando Alfonso, MD, Department of Cardiology, Hospital Universitario de La Princesa, Instituto de Investigación Sanitaria, IIS-IP, CIBER-CV, Universidad Autónoma de Madrid, c/ Diego de León 62, Madrid 28006, Spain, tel: +34 915202200, e-mail: falf@hotmail.com

Received: 10.08.2021 Accepted: 17.08.2021

This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.

The presence of coronary sinus (CS) venous valves is a major cause of coronary sinus reducer (SR) implant failure. A 69-year-old man with previous revascularization with triple coronary artery bypass grafting presented with limiting effort angina refractory to treatment. Recent angiography due to effort angina showed the occlusion of the two saphenous vein grafts and patency of the arterial graft to the left anterior descending coronary artery (LAD) and severe diffuse disease at the LAD and left circumflex coronary artery, which were considered not suitable to further revascularization. Due to persistent and refractory symptoms despite maximal medical therapy and objective evidence of anterolateral-induced ischemia, the patient was planned for SR implant.

A 9 Fr sheath was inserted through the right jugular vein and a multipurpose 6 F catheter was advanced into the right atrium. The CS venography disclosed the presence of a Vieussens valve at the proximal CS segment. Several attempts were made to cross the venous valve with the 9 F guiding catheter, including the use of a high-support extra-back up 0.35¨ guidewire and a mother and child technique using the 6 F catheter into the guiding catheter, but the system could not be advanced. Finally, a 5 × 15 mm balloon was inflated at 4 atm partially emerging out from the tip of the 9 F guiding catheter. Then, the guiding catheter could be readily advanced beyond the valve (balloon-assisted tracking technique). Subsequently, the SR stent was easily implanted in the mid segment of the CS. Final venography showed a good apposition of the SR, with a minimal confined dissection without any complication (Fig. 1).

199613.png

Figure 1. A. Retrograde coronary sinus (CS) venography showing the presence of a Vieussens valve (arrow); B. Guiding catheter advanced through the venous valve using the balloon-assisted tracking technique with a 5 mm balloon inflated at the tip of the guiding catheter (arrows); C. Coronary sinus reducer (SR) deployment in the CS; D. Final good angiographic result. A minimal dissection was present at the proximal edge of the SR (arrows).

Conflict of interest: None declared