Percutaneous closure of the inadvertent subclavian artery cannulation during pacemaker implantation

Xueying Chen1, Jin Bai1, Fei Han1, Daxin Zhou1, Yangang Su1
Pubmed: 28831782
Cardiol J 2017;24(4):452-454.

Abstract

N/A

Article available in PDF format

View PDF Download PDF file

References

  1. Kilbourne MJ, Bochicchio GV, Scalea T, et al. Avoiding common technical errors in subclavian central venous catheter placement. J Am Coll Surg. 2009; 208(1): 104–109.
  2. Shah PM, Babu SC, Goyal A, et al. Arterial misplacement of large-caliber cannulas during jugular vein catheterization: case for surgical management. J Am Coll Surg. 2004; 198(6): 939–944.
  3. Cipanio S, Oggionio R, Manganio V, et al. An accidental subclavian artery cannulation: successful catheter removal by percutaneous vascular stenting. Minerva Anestesiol. 2007; 73(4): 249–253.
  4. Nicholson T, Ettles D, Robinson G. Managing inadvertent arterial catheterization during central venous access procedures. Cardiovasc Intervent Radiol. 2004; 27(1): 21–25.
  5. Cohen JE, Moshe Gomori J, Anner H, et al. Inadvertent subclavian artery cannulation treated by percutaneous closure. J Clin Neurosci. 2014; 21(11): 1973–1975.
  6. Ananthakrishnan G, White RD, Bhat R, et al. Inadvertent subclavian artery cannulation: endovascular repair using a collagen closure device-report of two cases and review of the literature. Case Rep Vasc Med. 2012; 2012: 150343.
  7. Bangard C, Chang DH, Libicher M, et al. [Misplacement of central venous catheters in the subclavian artery: safe retrieval with a percutaneous closure device (AngioSeal)]. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2013; 185(6): 546–549.
  8. Devriendt A, Tran-Ngoc E, Gottignies P, et al. Ease of using a dedicated percutaneous closure device after inadvertent cannulation of the subclavian artery: case report. Case Rep Med. 2009; 2009: 728629.
  9. Kadner A, Schmidli J, Schwegler I, et al. Complications associated with the arterial puncture closure device: Angio-Seal. Vasc Endovascular Surg. 2008; 42(3): 225–227.
  10. Sharma M, Sakhuja R, Teitel D, et al. Percutaneous arterial closure for inadvertent cannulation of the subclavian artery: a call for caution. J Invasive Cardiol. 2008; 20(7): E229–E232.