Is AIO belly board device advantageous in all rectal cancer patients irradiated in the pelvic area?

Dominika Hempel, Joanna Mandrosz, Marek Z. Wojtukiewicz, Tomasz Filipowski, Ewa Sierko
Biuletyn Polskiego Towarzystwa Onkologicznego Nowotwory 2017;2(6):441-447.

dostęp otwarty

Tom 2, Nr 6 (2017)
Artykuły oryginalne / Original articles
Opublikowany online: 2018-06-12

Streszczenie

Purpose. To compare the prone position on a flat table vs an “All in one” belly board device (AIO BBD) in rectal cancer patients (RCPs).

Material and methods. Fifteen RCPs scheduled for irradiation were scanned in the two evaluated positions. After tomography, they completed a questionnaire concerning positioning. The dose-volume histograms (DVHs) for the small bowel and bladder were compared for both immobilization methods and setup accuracy was analyzed in electronic portal imaging devices (EPIDs) and X-ray volume imaging (XVI) procedures.

Results. AIO BBD was accepted by the majority of RCPs and provided better DVHs for the small bowel than the prone position on a flat table. The setup reproducibility was within tolerance limit for patients with BMI ≤ 29 kg/m2. Patients with obesity regarded AIO BBD as uncomfortable and they presented mean setup shifts out of the tolerance limit in the Y axis — 5.9 mm.

Conclusions. The AIO BBD should be recommended for RCPs, especially for those with BMI ≤ 29 kg/m2.

Streszczenie

Purpose. To compare the prone position on a flat table vs an “All in one” belly board device (AIO BBD) in rectal cancer patients (RCPs).

Material and methods. Fifteen RCPs scheduled for irradiation were scanned in the two evaluated positions. After tomography, they completed a questionnaire concerning positioning. The dose-volume histograms (DVHs) for the small bowel and bladder were compared for both immobilization methods and setup accuracy was analyzed in electronic portal imaging devices (EPIDs) and X-ray volume imaging (XVI) procedures.

Results. AIO BBD was accepted by the majority of RCPs and provided better DVHs for the small bowel than the prone position on a flat table. The setup reproducibility was within tolerance limit for patients with BMI ≤ 29 kg/m2. Patients with obesity regarded AIO BBD as uncomfortable and they presented mean setup shifts out of the tolerance limit in the Y axis — 5.9 mm.

Conclusions. The AIO BBD should be recommended for RCPs, especially for those with BMI ≤ 29 kg/m2.

Pobierz cytowanie

Słowa kluczowe

rectal cancer, AIO belly board device, small bowel exposure, setup shifts

Informacje o artykule
Tytuł

Is AIO belly board device advantageous in all rectal cancer patients irradiated in the pelvic area?

Czasopismo

Biuletyn Polskiego Towarzystwa Onkologicznego Nowotwory

Numer

Tom 2, Nr 6 (2017)

Strony

441-447

Opublikowany online

2018-06-12

Wyświetlenia strony

249

Wyświetlenia/pobrania artykułu

432

Rekord bibliograficzny

Biuletyn Polskiego Towarzystwa Onkologicznego Nowotwory 2017;2(6):441-447.

Słowa kluczowe

rectal cancer
AIO belly board device
small bowel exposure
setup shifts

Autorzy

Dominika Hempel
Joanna Mandrosz
Marek Z. Wojtukiewicz
Tomasz Filipowski
Ewa Sierko

Regulamin

Ważne: serwis https://journals.viamedica.pl/ wykorzystuje pliki cookies. Więcej >>

Używamy informacji zapisanych za pomocą plików cookies m.in. w celach statystycznych, dostosowania serwisu do potrzeb użytkownika (np. język interfejsu) i do obsługi logowania użytkowników. W ustawieniach przeglądarki internetowej można zmienić opcje dotyczące cookies. Korzystanie z serwisu bez zmiany ustawień dotyczących cookies oznacza, że będą one zapisane w pamięci komputera. Więcej informacji można znaleźć w naszej Polityce prywatności.

Czym są i do czego służą pliki cookie możesz dowiedzieć się na stronie wszystkoociasteczkach.pl.

Wydawcą serwisu jest VM Media Group sp. z o.o., ul. Świętokrzyska 73, 80–180 Gdańsk
tel.:+48 58 320 94 94, e-mail: viamedica@viamedica.pl