Abstract

Background: Due to the recent rapid increase in the number of patients implanted with pacemakers, cardioverter-defibrillators (ICD), and cardiac resynchronisation therapy devices (CRT), conventional monitoring at specialist clinics is becoming increasingly difficult. The development of technology has enabled remote device monitoring with the use of teletransmission systems.

Aim: To assess the effectiveness of transmission and the possibility of using telemetric data for further clinical management of patients with heart failure (HF) treated with CRT-D.

Methods: The analysis included 305 consecutive patients with chronic HF, New York Heart Association functional classes II–IV, treated with the use of CRT-D by Biotronik or Medtronic in the years 2006–2012. The patients received transmitters, enabling the remote monitoring of the implanted device from the patients’ houses. Scheduled reports were automatically sent every month. The triggers for pre-specified emergency alert transmissions were as follows: ventricular tachycardia (VT) or ventricular fibrillation (VF) episodes, CRT-D intervention, ventricular extrasystoles > 110/h, any episode of atrial fibrillation (AF), atrial flutter (AFL) or supraventricular tachycardia, mean heart rate (HR) during, mean 24-h HR, CRT pacing < 95%, Elective Replacement Indicator, or End Of Service and device malfunction. The all-cause mortality of the study population has been assessed at the end of the follow-up period (mean of 20.5 months).

Results: Devices manufactured by Biotronik were provided to 71% of the study population, while 29% received devices by Medtronic. In 97.3% of cases, the monitors were wireless, fully automatic, and capable of immediate data transmission whenever a pre-specified alert notification was fulfilled. The analysis of long-term outcomes revealed that all-cause mortality of the whole study population was 13%. The effectiveness of report transmission was 98%. During follow-up a total of 31,198 transmissions were received and analysed, which constituted, on average, 4.9 transmissions per patient per month. Among analyses, 30% were reports generated by scheduled remote follow-ups, and 70% were caused by unscheduled device alerts. Correct functioning of the system was confirmed; the quality of the received data was 100%. In 63.9% of patients, decisions based on the information obtained from telemonitoring reports were made to modify the therapy, refer the patients to cardiology or electrophysiology clinics, or hospitalise them urgently. The most common medical reaction was device reprogramming (46.8%). Pharmacotherapy was modified in 33.7% of patients: beta-blocker dose increase (25.9%), anticoagulant treatment inclusion (15.7%), amiodarone inclusion (1.9%), or digoxin inclusion (4.5%). The remaining medical responses were referring patients for atrioventricular junction ablation (8.1%), VT ablation (2.9%), or AF/AFl ablation (1.6%).

Conclusions: Remote monitoring of implantable devices is feasible, safe, and effective in supervising patients with CRT-D devices. Daily-based remote monitoring of a large population of HF patients allows continuous “triage” of high-risk patients and selection of individuals who require urgent intervention.

Abstract

Background: Due to the recent rapid increase in the number of patients implanted with pacemakers, cardioverter-defibrillators (ICD), and cardiac resynchronisation therapy devices (CRT), conventional monitoring at specialist clinics is becoming increasingly difficult. The development of technology has enabled remote device monitoring with the use of teletransmission systems.

Aim: To assess the effectiveness of transmission and the possibility of using telemetric data for further clinical management of patients with heart failure (HF) treated with CRT-D.

Methods: The analysis included 305 consecutive patients with chronic HF, New York Heart Association functional classes II–IV, treated with the use of CRT-D by Biotronik or Medtronic in the years 2006–2012. The patients received transmitters, enabling the remote monitoring of the implanted device from the patients’ houses. Scheduled reports were automatically sent every month. The triggers for pre-specified emergency alert transmissions were as follows: ventricular tachycardia (VT) or ventricular fibrillation (VF) episodes, CRT-D intervention, ventricular extrasystoles > 110/h, any episode of atrial fibrillation (AF), atrial flutter (AFL) or supraventricular tachycardia, mean heart rate (HR) during, mean 24-h HR, CRT pacing < 95%, Elective Replacement Indicator, or End Of Service and device malfunction. The all-cause mortality of the study population has been assessed at the end of the follow-up period (mean of 20.5 months).

Results: Devices manufactured by Biotronik were provided to 71% of the study population, while 29% received devices by Medtronic. In 97.3% of cases, the monitors were wireless, fully automatic, and capable of immediate data transmission whenever a pre-specified alert notification was fulfilled. The analysis of long-term outcomes revealed that all-cause mortality of the whole study population was 13%. The effectiveness of report transmission was 98%. During follow-up a total of 31,198 transmissions were received and analysed, which constituted, on average, 4.9 transmissions per patient per month. Among analyses, 30% were reports generated by scheduled remote follow-ups, and 70% were caused by unscheduled device alerts. Correct functioning of the system was confirmed; the quality of the received data was 100%. In 63.9% of patients, decisions based on the information obtained from telemonitoring reports were made to modify the therapy, refer the patients to cardiology or electrophysiology clinics, or hospitalise them urgently. The most common medical reaction was device reprogramming (46.8%). Pharmacotherapy was modified in 33.7% of patients: beta-blocker dose increase (25.9%), anticoagulant treatment inclusion (15.7%), amiodarone inclusion (1.9%), or digoxin inclusion (4.5%). The remaining medical responses were referring patients for atrioventricular junction ablation (8.1%), VT ablation (2.9%), or AF/AFl ablation (1.6%).

Conclusions: Remote monitoring of implantable devices is feasible, safe, and effective in supervising patients with CRT-D devices. Daily-based remote monitoring of a large population of HF patients allows continuous “triage” of high-risk patients and selection of individuals who require urgent intervention.

Get Citation

Keywords

remote monitoring, cardiac resynchronisation therapy, heart failure

About this article
Title

Day by day telemetric care of patients treated with cardiac resynchronisation therapy: first Polish experience

Journal

Kardiologia Polska (Polish Heart Journal)

Issue

Vol 74, No 8 (2016)

Pages

741-748

Published online

2016-01-26

DOI

10.5603/KP.a2016.0019

Bibliographic record

Kardiol Pol 2016;74(8):741-748.

Keywords

remote monitoring
cardiac resynchronisation therapy
heart failure

Authors

Agnieszka Liberska
Oskar Kowalski
Michał Mazurek
Radosław Lenarczyk
Ewa Jędrzejczyk-Patej
Katarzyna Przybylska-Siedlecka
Monika Kozieł
Stanisław Morawski
Tomasz Podolecki
Jacek Kowalczyk
Patrycja Pruszkowska
Sławomir Pluta
Adam Sokal
Zbigniew Kalarus

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Sp. z o.o. VM Group Sp.k., ul. Świętokrzyska 73 , 80–180 Gdańsk, Poland

phone:+48 58 320 94 94, fax:+48 58 320 94 60, e-mail: viamedica@viamedica.pl