Long-term follow-up of mesh-covered stent implantation in patients with ST-segment elevation myocardial infarction

Dariusz Dudek, Artur Dziewierz, Paweł Kleczyński, Dawid Giszterowicz, Tomasz Rakowski, Danuta Sorysz, Łukasz Rzeszutko, Jacek Legutko, Stanisław Bartuś, Jacek Dragan, Artur Klecha, Zbigniew Siudak, Krzysztof Żmudka
Kardiol Pol 2014;72(2):140-145.

Abstract

Background: The MGuard stent (a bare-metal stent wrapped externally in a polymer mesh sleeve) was introduced to reduce the risk of distal embolisation and no-reflow phenomenon during percutaneous coronary intervention (PCI) in thrombus containing lesions, including ST-segment elevation myocardial infarction (STEMI). However, data on the long-term performance of the MGuard stent is limited.

Aim: To assess the long-term safety and efficacy of MGuard stent implantation during primary PCI for STEMI.

Methods and results: In this multicentre study, a total of 60 patients with STEMI ≤ 12 h treated with the MGuard stent were enrolled. Angiographic success of PCI was achieved in 96.7%, with the final TIMI grade 3 flow in 90.0% of patients. At six months, the overall rate of major adverse cardiac and cerebrovascular events (MACCE; composite of cardiac death, nonfatal target vessel reinfarction, target lesion revascularisation, and stroke) was 1.7%. A long-term follow-up of the study was successfully performed in 57 patients (mean follow-up of 38.7 ± 3.1 months). The long-term cardiac mortality was 7.0%, with a MACCE rate of 8.8%. There was no decrease in the left ventricular ejection fraction and no enlargement of the left ventriclebetween index and long-term follow-up echocardiogram.

Conclusions: The early safety and efficacy of the MGuard stent was maintained during the long-term follow-up. However, comparative data from ongoing randomised clinical trials are still required to confirm the long-term efficacy of MGuard stent implantation in patients with STEMI.