open access

Vol 79, No 2 (2020)
Original article
Submitted: 2019-04-04
Accepted: 2019-05-24
Published online: 2019-06-27
Get Citation

Diversity of coronary arterial tree in laboratory mice

D. Kłosińska1, B. Ciszek2, B. Majchrzak3, I. Badurek3, A. Ratajska3
·
Pubmed: 31257564
·
Folia Morphol 2020;79(2):255-264.
Affiliations
  1. Division of Histology and Embryology, Department of Morphological Sciences, Fakulty of Veterinary Medicine, Warsaw University of Life Sciences, Nowoursynowska, 01-151 Warsaw, Poland
  2. Department of Clinical Anatomy, Medical University of Warsaw, Chałubińskiego 5, 02-004 Warsaw, Poland
  3. Department of Pathology, Medical University of Warsaw, ul. Chałubińskiego 5, 02–004 Warszawa, Poland

open access

Vol 79, No 2 (2020)
ORIGINAL ARTICLES
Submitted: 2019-04-04
Accepted: 2019-05-24
Published online: 2019-06-27

Abstract

Background: Research on the development and topography of mouse coronary arteries has been conducted for many years. Patterns of the course of these vessels have been described in various mouse strains. Our research focused on hearts of MIZZ mice.

Materials and methods: We visualised the coronary artery system by means of latex dye perfusion via the aorta. The injected latex did not reach the capillary vessel system.

Results: The heart of MIZZ mice is supplied with blood by two main coronary arteries: the right and the left one. They deliver blood to the right and left part of the heart, respectively. The right coronary artery arises from the right sinus of the aorta and the left coronary artery from the left sinus. The interventricular septum is usually supplied by the septal artery, which is the main branch of the right coronary artery. All arteries of the coronary system run intramurally. The number of branches and the location of their ostia differed among the examined individuals.

Conclusions: Detailed information about the normal topography of coronary arteries, the number and course of their branches, as well as the area of the heart which is vascularised by these vessels constitutes the basic knowledge necessary to conduct further experiments.

Abstract

Background: Research on the development and topography of mouse coronary arteries has been conducted for many years. Patterns of the course of these vessels have been described in various mouse strains. Our research focused on hearts of MIZZ mice.

Materials and methods: We visualised the coronary artery system by means of latex dye perfusion via the aorta. The injected latex did not reach the capillary vessel system.

Results: The heart of MIZZ mice is supplied with blood by two main coronary arteries: the right and the left one. They deliver blood to the right and left part of the heart, respectively. The right coronary artery arises from the right sinus of the aorta and the left coronary artery from the left sinus. The interventricular septum is usually supplied by the septal artery, which is the main branch of the right coronary artery. All arteries of the coronary system run intramurally. The number of branches and the location of their ostia differed among the examined individuals.

Conclusions: Detailed information about the normal topography of coronary arteries, the number and course of their branches, as well as the area of the heart which is vascularised by these vessels constitutes the basic knowledge necessary to conduct further experiments.

Get Citation

Keywords

coronary artery, heart, septal artery, right coronary artery, mouse

About this article
Title

Diversity of coronary arterial tree in laboratory mice

Journal

Folia Morphologica

Issue

Vol 79, No 2 (2020)

Article type

Original article

Pages

255-264

Published online

2019-06-27

Page views

1646

Article views/downloads

906

DOI

10.5603/FM.a2019.0070

Pubmed

31257564

Bibliographic record

Folia Morphol 2020;79(2):255-264.

Keywords

coronary artery
heart
septal artery
right coronary artery
mouse

Authors

D. Kłosińska
B. Ciszek
B. Majchrzak
I. Badurek
A. Ratajska

References (35)
  1. Ahmed SH, Rakhawy MT, Abdalla A, et al. The comparative anatomy of the blood supply of cardiac ventricles in the albino rat and guinea-pig. J Anat. 1978; 126(Pt 1): 51–57.
  2. Andrade JN, Tang J, Hensley MT, et al. Rapid and efficient production of coronary artery ligation and myocardial infarction in mice using surgical clips. PLoS One. 2015; 10(11): e0143221.
  3. Arque JM, Cruz V, Rosado LM, et al. Congenital anomalies of coronary arteries in rodents. Am J Cardiol. 1986; 57(6): 498–499.
  4. Barth C, Roberts W. Left main coronary artery originating from the right sinus of valsalva and coursing between the aorta and pulmonary trunk. J Am Coll Cardiol. 1986; 7(2): 366–373.
  5. Basso C, Maron B, Corrado D, et al. Clinical profile of congenital coronary artery anomalies with origin from the wrong aortic sinus leading to sudden death in young competitive athletes. J Am Coll Cardiol. 2000; 35(6): 1493–1501.
  6. Becker AE. Variations of the main coronary arteries. In: Becker AE, Losekoot G, Marcelletti C, Anderson RH, editors. Paediatric Cardiology. 1981: 263–77.
  7. Buehler A, Martire A, Strohm C, et al. Angiogenesis-independent cardioprotection in FGF-1 transgenic mice. Cardiovasc Res. 2002; 55(4): 768–777.
  8. Cheitlin MD, De Castro CM, McAllister HA. Sudden death as a complication of anomalous left coronary origin from the anterior sinus of Valsalva, A not-so-minor congenital anomaly. Circulation. 1974; 50(4): 780–787.
  9. Cheng Ke, Ibrahim A, Hensley MT, et al. Relative roles of CD90 and c-kit to the regenerative efficacy of cardiosphere-derived cells in humans and in a mouse model of myocardial infarction. J Am Heart Assoc. 2014; 3(5): e001260.
  10. Ciszek B, Skubiszewska D, Ratajska A. The anatomy of the cardiac veins in mice. J Anat. 2007; 211(1): 53–63.
  11. Clauss SB, Walker DL, Kirby ML, et al. Patterning of coronary arteries in wildtype and connexin43 knockout mice. Dev Dyn. 2006; 235(10): 2786–2794.
  12. Desmet W, Vanhaecke J, Vrolix M, et al. Isolated single coronary artery: a review of 50,000 consecutive coronary angiographies. Eur Heart J. 1992; 13(12): 1637–1640.
  13. Durán AC, Fernández-Gallego T, Fernández B, et al. Solitary coronary ostium in the aorta in Syrian hamsters. A morphological study of 130 cases. Cardiovasc Pathol. 2005; 14(6): 303–311.
  14. Durán A, Sans-Coma V, Arqué J, et al. Blood supply to the interventricular septum of the heart in rodents with intramyocardial coronary arteries. Acta Zoologica. 1992; 73(4): 223–229.
  15. Fernández B, Durán AC, Fernández MC, et al. The coronary arteries of the C57BL/6 mouse strains: implications for comparison with mutant models. J Anat. 2008; 212(1): 12–18.
  16. Fernandez B, Duran AC, LJ P. How many coronary arteries are there in mammals? . J Morphol. 2007; 268(1072).
  17. Flaht-Zabost A, Gula G, Ciszek B, et al. Cardiac mouse lymphatics: developmental and anatomical update. Anat Rec (Hoboken). 2014; 297(6): 1115–1130.
  18. González-Iriarte M, Carmona R, Pérez-Pomares JM, et al. Development of the coronary arteries in a murine model of transposition of great arteries. J Mol Cell Cardiol. 2003; 35(7): 795–802.
  19. Guinovart MP, Vilallonga JR. Arterias coronarias: aspectos anatomo-clínicos:. Ediciones Científicas y Técnicas. 1993.
  20. Guo Y, Wu WJ, Qiu Y, et al. Demonstration of an early and a late phase of ischemic preconditioning in mice. Am J Physiol. 1998; 275(4): H1375–H1387.
  21. Icardo JM, Colvee E. Origin and course of the coronary arteries in normal mice and in iv/iv mice. J Anat. 2001; 199(Pt 4): 473–482.
  22. Jones SP, Tang XL, Guo Y, et al. The NHLBI-sponsored Consortium for preclinicAl assESsment of cARdioprotective therapies (CAESAR): a new paradigm for rigorous, accurate, and reproducible evaluation of putative infarct-sparing interventions in mice, rabbits, and pigs. Circ Res. 2015; 116(4): 572–586.
  23. Juszyński M, Ciszek B, Stachurska E, et al. Development of lymphatic vessels in mouse embryonic and early postnatal hearts. Dev Dyn. 2008; 237(10): 2973–2986.
  24. Kolesová H, Bartoš M, Hsieh WC, et al. Novel approaches to study coronary vasculature development in mice. Dev Dyn. 2018; 247(8): 1018–1027.
  25. Lewis FT. The question of Sinusoids. Anat Anz. 1904; 25: 261–269.
  26. Li WE, Waldo K, Linask KL, et al. An essential role for connexin43 gap junctions in mouse coronary artery development. Development. 2002; 129(8): 2031–2042.
  27. Liberthson RR, Dinsmore RE, Fallon JT. Aberrant coronary artery origin from the aorta. Report of 18 patients, review of literature and delineation of natural history and management. Circulation. 1979; 59(4): 748–754.
  28. López-García A, Soto-Navarrete MT, Fernández MC, et al. Unusual anatomical origins of the coronary arteries in C57BL/6 mice. Are they strain-specific? J Anat. 2016; 229(5): 703–709.
  29. Makkar RR, Smith RR, Cheng Ke, et al. Intracoronary cardiosphere-derived cells for heart regeneration after myocardial infarction (CADUCEUS): a prospective, randomised phase 1 trial. Lancet. 2012; 379(9819): 895–904.
  30. Michael LH, Entman ML, Hartley CJ, et al. Myocardial ischemia and reperfusion: a murine model. Am J Physiol. 1995; 269(6 Pt 2): H2147–H2154.
  31. Ratajska A, Gula G, Flaht-Zabost A, et al. Comparative and developmental anatomy of cardiac lymphatics. Scien World J. 2014; 2014: 183170.
  32. Salto-Tellez M, Lim SY, Oakley REl, et al. Myocardial infarction in the C57BL/6J mouse. Cardiovasc Pathol. 2004; 13(2): 91–97.
  33. Sans-Coma V, Arqué JM, Durán AC, et al. The coronary arteries of the Syrian hamster, Mesocricetus auratus (Waterhouse 1839). Ann Anatom. 1993; 175(1): 53–57.
  34. Vandergriff AC, Hensley TM, Henry ET, et al. Magnetic targeting of cardiosphere-derived stem cells with ferumoxytol nanoparticles for treating rats with myocardial infarction. Biomaterials. 2014; 35(30): 8528–8539.
  35. Wollert KC, Drexler H. Clinical applications of stem cells for the heart. Circ Res. 2005; 96(2): 151–163.

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., Grupa Via Medica, Świętokrzyska 73, 80–180 Gdańsk, Poland

tel.: +48 58 320 94 94, faks: +48 58 320 94 60, e-mail: viamedica@viamedica.pl