Acute dislocation of fully deployed stent after use of non-compliant balloon: an enigma

Santosh Kumar Sinha, Mahmadulla Razi, Ramesh Thakur, Mukesh Jitendra Jha, Amit Goel, Vikas Mishra, Ashutosh Kumar
DOI: 10.5603/FC.2016.0035
·
Folia Cardiologica 2016;11(3):222-225.

open access

Vol 11, No 3 (2016)
Case Reports
Published online: 2016-07-13

Abstract

Stent embolism is an established but rare complication of percutaneous coronary intervention, usually encountered when an undeployed stent unintentionally dislocates from the balloon. Published literature regarding incidence or clinical outcomes of embolism of fully deployed coronary stents is sparse. Here we report an unusual case of a 41-year-old male who had dislocation of a fully deployed stent into the distal part of left anterior descending artery following post dilatation by non-compliant balloon during percutaneous coronary intervention.

Abstract

Stent embolism is an established but rare complication of percutaneous coronary intervention, usually encountered when an undeployed stent unintentionally dislocates from the balloon. Published literature regarding incidence or clinical outcomes of embolism of fully deployed coronary stents is sparse. Here we report an unusual case of a 41-year-old male who had dislocation of a fully deployed stent into the distal part of left anterior descending artery following post dilatation by non-compliant balloon during percutaneous coronary intervention.

Get Citation

Keywords

left anterior descending artery, dislocation of deployed stent, non-compliant balloon

About this article
Title

Acute dislocation of fully deployed stent after use of non-compliant balloon: an enigma

Journal

Folia Cardiologica

Issue

Vol 11, No 3 (2016)

Pages

222-225

Published online

2016-07-13

DOI

10.5603/FC.2016.0035

Bibliographic record

Folia Cardiologica 2016;11(3):222-225.

Keywords

left anterior descending artery
dislocation of deployed stent
non-compliant balloon

Authors

Santosh Kumar Sinha
Mahmadulla Razi
Ramesh Thakur
Mukesh Jitendra Jha
Amit Goel
Vikas Mishra
Ashutosh Kumar

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

 