Alternative methods for functional assessment of intermediate coronary lesions

Martyna Zaleska1, Łukasz Kołtowski1, Jakub Maksym1, Mariusz Tomaniak1, Maksymilian Opolski2, Janusz Kochman1
Pubmed: 30912574
Cardiol J 2020;27(6):825-835.

Abstract

Wire-based fractional flow reserve (FFR) is a diagnostic tool used to evaluate the ischemic burden of coronary lesions. Large-scale studies have shown that FFR-guided revascularization is associated with better clinical outcomes. However, wide adoption of this technology is limited due to the considerable cost, additional time needed for set-up and performance of the measurement as well as the invasiveness of the procedure which requires pressure wire placement across the lesion into the distal segment of the coronary artery. To overcome these limitations new, promising, and less-/non-invasive methods were developed. These methods are based on computational fluid dynamics analysis and three-dimensional lumen reconstruction. The aim of this paper is to review scientific evidence supporting the clinical safety and efficacy of these techniques, such as instantaneous wave-free ratio, quantitative flow ratio and FFR calculated from computed tomographic angiography.

Article available in PDF format

View PDF Download PDF file

References

  1. Mendis S, Davis S, Norrving Bo. Organizational update: the world health organization global status report on noncommunicable diseases 2014; one more landmark step in the combat against stroke and vascular disease. Stroke. 2015; 46(5): e121–e122.
  2. Global, regional, and national age–sex specific all-cause and cause-specific mortality for 240 causes of death, 1990–2013: a systematic analysis for the Global Burden of Disease Study 2013. The Lancet. 2015; 385(9963): 117–171.
  3. Toth G, Toth B, Johnson N, et al. Revascularization decisions in patients with stable angina and intermediate lesions. Circ Cardiovasc Interv. 2014; 7(6): 751–759.
  4. Biały D, Wawrzyńska M, Arkowski J, et al. Multimodality imaging of intermediate lesions: Data from fractional flow reserve, optical coherence tomography, near-infrared spectroscopy-intravascular ultrasound. Cardiol J. 2018; 25(2): 196–202.
  5. Dattilo PB, Prasad A, Honeycutt E, et al. Contemporary patterns of fractional flow reserve and intravascular ultrasound use among patients undergoing percutaneous coronary intervention in the United States: insights from the National Cardiovascular Data Registry. J Am Coll Cardiol. 2012; 60(22): 2337–2339.
  6. Dehmer GJ, Weaver D, Roe MT, et al. A contemporary view of diagnostic cardiac catheterization and percutaneous coronary intervention in the United States: a report from the CathPCI Registry of the National Cardiovascular Data Registry, 2010 through June 2011. J Am Coll Cardiol. 2012; 60(20): 2017–2031.
  7. Härle T, Zeymer U, Hochadel M, et al. Real-world use of fractional flow reserve in Germany: results of the prospective ALKK coronary angiography and PCI registry. Clin Res Cardiol. 2017; 106(2): 140–150.
  8. Ochała A, Siudak Z, Legutko J, et al. Percutaneous interventions in cardiology in Poland in the year 2014. Summary report of the Association of Cardiovascular Interventions of the Polish Cardiac Society AISN PTK. Postepy Kardiol Interwencyjnej. 2015; 11(3): 177–181.
  9. Kumsars I, Narbute I, Thuesen L, et al. Side branch fractional flow reserve measurements after main vessel stenting: a Nordic-Baltic Bifurcation Study III substudy. EuroIntervention. 2012; 7(10): 1155–1161.
  10. Curzen N, Rana O, Nicholas Z, et al. Does routine pressure wire assessment influence management strategy at coronary angiography for diagnosis of chest pain?: the RIPCORD study. Circ Cardiovasc Interv. 2014; 7(2): 248–255.
  11. Park E, Price A, Vidovich MI. Adenosine-induced atrial fibrillation during fractional flow reserve measurement. Cardiol J. 2012; 19(6): 650–651.
  12. Tu S, Barbato E, Köszegi Z, et al. Fractional flow reserve calculation from 3-dimensional quantitative coronary angiography and TIMI frame count: a fast computer model to quantify the functional significance of moderately obstructed coronary arteries. JACC Cardiovasc Interv. 2014; 7(7): 768–777.
  13. Morris PD, Ryan D, Morton AC, et al. Virtual fractional flow reserve from coronary angiography: modeling the significance of coronary lesions: results from the VIRTU-1 (VIRTUal Fractional Flow Reserve From Coronary Angiography) study. JACC Cardiovasc Interv. 2013; 6(2): 149–157.
  14. Koo BK, Erglis A, Doh JH, et al. Diagnosis of ischemia-causing coronary stenoses by noninvasive fractional flow reserve computed from coronary computed tomographic angiograms. Results from the prospective multicenter DISCOVER-FLOW (Diagnosis of Ischemia-Causing Stenoses Obtained Via Noninvasive Fractional Flow Reserve) study. J Am Coll Cardiol. 2011; 58(19): 1989–1997.
  15. Min JK, Leipsic J, Pencina MJ, et al. Diagnostic accuracy of fractional flow reserve from anatomic CT angiography. JAMA. 2012; 308(12): 1237–1245.
  16. Nørgaard BL, Leipsic J, Gaur S, et al. Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). J Am Coll Cardiol. 2014; 63(12): 1145–1155.
  17. Sen S, Escaned J, Malik IS, et al. Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis: results of the ADVISE (ADenosine Vasodilator Independent Stenosis Evaluation) study. J Am Coll Cardiol. 2012; 59(15): 1392–1402.
  18. Petraco R, Al-Lamee R, Gotberg M, et al. Real-time use of instantaneous wave-free ratio: results of the ADVISE in-practice: an international, multicenter evaluation of instantaneous wave-free ratio in clinical practice. Am Heart J. 2014; 168(5): 739–748.
  19. Petraco R, Hoef Tv, Nijjer S, et al. Baseline instantaneous wave-free ratio as a pressure-only estimation of underlying coronary flow reserve. Circ Cardiovasc Interv. 2014; 7(4): 492–502.
  20. Davies JE, Sen S, Dehbi HM, et al. Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI. N Engl J Med. 2017; 376(19): 1824–1834.
  21. Götberg M, Christiansen EH, Gudmundsdottir IJ, et al. Instantaneous wave-free ratio versus fractional flow reserve to guide PCI. N Engl J Med. 2017; 376(19): 1813–1823.
  22. Neumann FJ, Sousa-Uva M, Ahlsson A, et al. 2018 ESC/EACTS Guidelines on myocardial revascularization. Eur Heart J. 2018.
  23. Patel M, Calhoon J, Dehmer G, et al. ACC/AATS/AHA/ASE/ASNC/SCAI/SCCT/STS 2017 Appropriate Use Criteria for Coronary Revascularization in Patients With Stable Ischemic Heart Disease. J Nucl Cardiol. 2017; 24(5): 1759–1792.
  24. Lee JM, Park J, Hwang D, et al. Similarity and difference of resting distal to aortic coronary pressure and Instantaneous wave-free ratio. J Am Coll Cardiol. 2017; 70(17): 2114–2123.
  25. Kobayashi Y, Johnson NP, Zimmermann FM, et al. Agreement of the resting distal to Aortic Coronary pressure with the Instantaneous wave-free ratio. J Am Coll Cardiol. 2017; 70(17): 2105–2113.
  26. Van't Veer M, Pijls NHJ, Hennigan B, et al. Comparison of Different Diastolic Resting Indexes to iFR: Are They All Equal? J Am Coll Cardiol. 2017; 70(25): 3088–3096.
  27. Papafaklis MI, Muramatsu T, Ishibashi Y, et al. Fast virtual functional assessment of intermediate coronary lesions using routine angiographic data and blood flow simulation in humans: comparison with pressure wire - fractional flow reserve. EuroIntervention. 2014; 10(5): 574–583.
  28. Lansky AJ, Pietras C. Fractional flow reserve from 3-dimensional quantitative coronary angiography: fresh light through an old window. JACC Cardiovasc Interv. 2014; 7(7): 778–780.
  29. Tu S, Westra J, Yang J, et al. Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the international multicenter FAVOR pilot study. JACC Cardiovasc Interv. 2016; 9(19): 2024–2035.
  30. Xu Bo, Tu S, Qiao S, et al. Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol. 2017; 70(25): 3077–3087.
  31. Kołtowski Ł, Zaleska M, Maksym J, et al. Quantitative flow ratio derived from diagnostic coronary angiography in assessment of patients with intermediate coronary stenosis: a wire-free fractional flow reserve study. Clin Res Cardiol. 2018; 107(9): 858–867.
  32. Westra J, Tu S, Winther S, et al. Evaluation of coronary artery stenosis by quantitative flow ratio during invasive coronary angiography: the WIFI II study (wire-free functional imaging II). Circ Cardiovasc Imaging. 2018; 11(3): e007107.
  33. Westra J, Andersen BK, Campo G, et al. Diagnostic performance of in-procedure angiography-derived quantitative flow reserve compared to pressure-derived fractional flow reserve: the FAVOR II europe-japan study. J Am Heart Assoc. 2018; 7(14).
  34. Spitaleri G, Tebaldi M, Biscaglia S, et al. Quantitative flow ratio identifies nonculprit coronary lesions requiring revascularization in patients with st-segment-elevation myocardial infarction and multivessel disease. Circ Cardiovasc Interv. 2018; 11(2): e006023.
  35. Chang Y, Chen L, Westra J, et al. Reproducibility of quantitative flow ratio: An inter-core laboratory variability study. Cardiol J. 2018 [Epub ahead of print].
  36. Douglas PS, Pontone G, Hlatky MA, et al. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFR(CT): outcome and resource impacts study. Eur Heart J. 2015; 36(47): 3359–3367.
  37. Nørgaard BL, Terkelsen CJ, Mathiassen ON, et al. Coronary CT angiographic and flow reserve-guided management of patients with stable ischemic heart disease. J Am Coll Cardiol. 2018; 72(18): 2123–2134.
  38. Zarins CK, Taylor CA, Min JK. Computed fractional flow reserve (FFTCT) derived from coronary CT angiography. J Cardiovasc Transl Res. 2013; 6(5): 708–714.
  39. Gaur S, Taylor CA, Jensen JM, et al. FFR derived from coronary CT angiography in Nonculprit Lesions of patients with recent stemi. JACC Cardiovasc Imaging. 2017; 10(4): 424–433.