Analyzing the formation of normal and abnormal O waves in thoracic impedance graph using the impedance change components for aorta, blood vessels in lung and ventricles

Nan-Zhen Kuang, Qiu-Jin Xiao, Bai-Qing He, Jing-Juan Fu, Ming-Xing Kuang
DOI: 10.5603/CJ.a2014.0014
·
Cardiol J 2014;21(2):176-182.

open access

Vol 21, No 2 (2014)
Original articles
Submitted: 2013-04-08
Accepted: 2013-12-18
Published online: 2014-04-15

Abstract

Background: Many measurements of thoracic impedance graph show that the small C wave and big O wave appear often for patients with cardiac insufficiency, and the O/C ratio is bigger. And for the normal body, especially a younger one, the bigger O wave may also appear. But since the amplitude of the C wave of a normal body is bigger, the O/C ratio is smaller. The aim of the present paper is to investigate the formation mechanism of the normal and abnormal O waves in thoracic impedance graph.

Methods and Results: The thoracic mixed impedance changes are measured with 6 leads consisting of 15 electrodes. The impedance change components for the aorta (AO), blood vessel in left lung (PL), blood vessel in right lung (PR), left ventricle (LV) and right ventricle (RV) are separated from thoracic mixed impedance changes by means of establishing and solving the thoracic impedance equations. The amplitudes of the O and C waves of various impedance change components are measured for 50 normal healthy adults and 34 patients with cardiac insufficiency. The formation mechanism of normal and abnormal O waves in thoracic impedance graph is analyzed using the superposition of the O waves of the above impedance change components. Detection subjects are 50 healthy adults and 34 hospital patients with cardiac insufficiency. (1) Thoracic impedance graph: The O/C ratios of the normal group are significantly smaller than that of the abnormal group, p < 0.001. The O wave of first lead (E1-E1’) is significantly bigger than that of leads 4 and 5 (E4-E4’ and E5-E5’) in the normal group, p < 0.001. (2) The impedance change component: The O waves of the AO, PL, and PR are significantly smaller than that of the LV and RV in the normal group, p < 0.001. The O wave and O/C of the AO, PL and PR of normal group are significantly smaller than that of the abnormal group, p < 0.001.

Conclusions: The O wave of the thoracic impedance graph is formed due to the superposition of the O waves of the impedance change components for the aorta, blood vessels in lung and ventricles.

Abstract

Background: Many measurements of thoracic impedance graph show that the small C wave and big O wave appear often for patients with cardiac insufficiency, and the O/C ratio is bigger. And for the normal body, especially a younger one, the bigger O wave may also appear. But since the amplitude of the C wave of a normal body is bigger, the O/C ratio is smaller. The aim of the present paper is to investigate the formation mechanism of the normal and abnormal O waves in thoracic impedance graph.

Methods and Results: The thoracic mixed impedance changes are measured with 6 leads consisting of 15 electrodes. The impedance change components for the aorta (AO), blood vessel in left lung (PL), blood vessel in right lung (PR), left ventricle (LV) and right ventricle (RV) are separated from thoracic mixed impedance changes by means of establishing and solving the thoracic impedance equations. The amplitudes of the O and C waves of various impedance change components are measured for 50 normal healthy adults and 34 patients with cardiac insufficiency. The formation mechanism of normal and abnormal O waves in thoracic impedance graph is analyzed using the superposition of the O waves of the above impedance change components. Detection subjects are 50 healthy adults and 34 hospital patients with cardiac insufficiency. (1) Thoracic impedance graph: The O/C ratios of the normal group are significantly smaller than that of the abnormal group, p < 0.001. The O wave of first lead (E1-E1’) is significantly bigger than that of leads 4 and 5 (E4-E4’ and E5-E5’) in the normal group, p < 0.001. (2) The impedance change component: The O waves of the AO, PL, and PR are significantly smaller than that of the LV and RV in the normal group, p < 0.001. The O wave and O/C of the AO, PL and PR of normal group are significantly smaller than that of the abnormal group, p < 0.001.

Conclusions: The O wave of the thoracic impedance graph is formed due to the superposition of the O waves of the impedance change components for the aorta, blood vessels in lung and ventricles.

Get Citation

Keywords

thoracic impedance graph, impedance change component, O wave, superposition, formation

About this article
Title

Analyzing the formation of normal and abnormal O waves in thoracic impedance graph using the impedance change components for aorta, blood vessels in lung and ventricles

Journal

Cardiology Journal

Issue

Vol 21, No 2 (2014)

Pages

176-182

Published online

2014-04-15

Page views

1354

Article views/downloads

1429

DOI

10.5603/CJ.a2014.0014

Bibliographic record

Cardiol J 2014;21(2):176-182.

Keywords

thoracic impedance graph
impedance change component
O wave
superposition
formation

Authors

Nan-Zhen Kuang
Qiu-Jin Xiao
Bai-Qing He
Jing-Juan Fu
Ming-Xing Kuang

Regulations

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

By VM Media Group sp. z o.o., Grupa Via Medica, ul. Świętokrzyska 73, 80–180 Gdańsk, Poland
tel.:+48 58 320 94 94, fax:+48 58 320 94 60, e-mail: viamedica@viamedica.pl