Tom 9, Nr 3 (2024)
Artykuł przeglądowy
Opublikowany online: 2024-07-29

dostęp otwarty

Wyświetlenia strony 149
Wyświetlenia/pobrania artykułu 76
Pobierz cytowanie

Eksport do Mediów Społecznościowych

Eksport do Mediów Społecznościowych

Artykuł przeglądowy / Review article
Patologia nowotworów / Tumor pathology

Biuletyn Polskiego
Towarzystwa Onkologicznego
NOWOTWORY

2024, tom 9, nr 3, 256–261

© Polskie Towarzystwo Onkologiczne

ISSN: 2543–5248, e-ISSN: 2543–8077

www.nowotwory.edu.pl

The Paris System for Reporting Urinary Cytology a critical review of its role in advancing precision diagnostics with insights into artificial intelligence integration

Irmina M. Michałek1Monika Durzyńska1Florentino L. Caetano dos Santos2
1Department of Pathology, Maria Sklodowska-Curie National Research Institute of Oncology, Warsaw, Poland
2Harvard Business School, Harvard University, Boston, MA, USA
Urinary cytology serves as a vital diagnostic tool for urothelial carcinoma, offering a non-invasive screening method and guiding treatment decisions. The Paris System for Reporting Urinary Cytology (TPS) addresses historical challenges, providing a structured framework and enhancing diagnostic precision. The review explores the integration of artificial intelligence (AI) into urinary cytology, emphasizing its collaborative potential with TPS. A systematic literature review analyzes AI applications, revealing promising advancements but highlighting concerns about generalizability and overreliance on deep learning. The study underscores the importance of collaborative efforts for successful AI implementation, addressing challenges and ensuring seamless integration into clinical practice. While the synergy between TPS and AI shows promise, cautious consideration is necessary for widespread and reliable adoption, emphasizing ongoing refinement and validation.
Key words: urinary cytology, urothelial carcinoma, The Paris System for Reporting Urinary Cytology, precision diagnostics, standardized reporting, diagnostic challenges, clinical implications

Jak cytować / How to cite:

Michałek IM, Durzyńska M, Caetano dos Santos FL. The Paris System for Reporting Urinary Cytology a critical review of its role in advancing precision diagnostics with insights into artificial intelligence integration. NOWOTWORY J Oncol 2024; 74: 232–237.

Introduction

Urinary cytology plays an important role in the diagnosis of urothelial carcinoma, a type of cancer that primarily affects the urinary tract, including the bladder, ureters, and renal pelvis [1]. The significance of urinary cytology lies in its ability to detect abnormal cells shed from the lining of the urinary tract into the urine. These cells, when carefully examined under a microscope, can provide valuable information about the presence of urothelial carcinoma and its potential aggressiveness.

Urinary cytology emerges as a pivotal diagnostic modality in urothelial carcinoma, providing a multifaceted approach to enhance patient care. The non-invasive screening capability of urinary cytology offers a straightforward and repeatable method, making it an invaluable tool for routine monitoring, especially in high-risk populations with a history of bladder cancer. Complementary to advanced imaging studies such as cystoscopy, urinary cytology contributes unique insights at the cellular level, confirming the presence of cancerous cells and guiding subsequent diagnostic and treatment decisions [1].

One of the distinctive strengths of urinary cytology lies in its capacity to reduce the necessity for invasive procedures. The non-invasive nature of urine sample collection minimizes patient discomfort and contributes to a more patient-friendly diagnostic approach. In cases where urinary cytology indicates a low likelihood of urothelial carcinoma, unnecessary invasive interventions may be avoided, aligning with the principles of personalized and targeted medicine.

The Paris System for Reporting Urinary Cytology (TPS) is a standardized classification system designed to improve the consistency and precision of reporting urinary cytology, providing distinct categories with defined clinical implications [2, 3]. Before TPS, interpreting results faced challenges, including subjective interpretations, lack of standardized criteria, and inconsistencies [2, 4]. Pathologists used varied terminology, leading to confusion, while different classification systems hindered result comparison. Limited interobserver agreement and unclear clinical implications posed further issues, risking overdiagnosis or underdiagnosis. TPS addressed these challenges, offering a structured framework, improving consistency, and enhancing clinical utility in urinary cytology reporting [5].

This review aims to analyze TPS’s effectiveness in overcoming historical challenges. Additionally, the research explores artificial intelligence (AI) and image processing integration in urinary cytology, emphasizing image analysis, pattern recognition, and potential contributions to personalized treatment strategies. Anticipated findings aim to enhance understanding of the synergistic relationship between TPS and AI, illuminating their potential to revolutionize urinary cytology reporting for improved diagnostic precision in oncology.

Overview of TPS

The TPS introduces a structured classification system comprising categories with distinct clinical implications [2, 3]. TPS categorizes specimens as non-diagnostic, negative for high-grade urothelial carcinoma, atypical urothelial cells, suspicious for high-grade urothelial carcinoma, high-grade urothelial carcinoma, and other malignancies. This standardized approach addresses the historical lack of uniformity, providing clear criteria for each category. TPS significantly improves communication between pathologists and clinicians, ensuring a consistent understanding of findings, and facilitating informed decision-making in patient management.

The TPS demonstrates notable strengths in enhancing diagnostic precision. Its standardized categories provide a clear and consistent framework, reducing the subjectivity that previously characterized urinary cytology reporting. The structured approach, including categories like “atypical urothelial cells” and “suspicious for high-grade urothelial carcinoma,” facilitates more accurate and reliable interpretations [6]. By offering well-defined criteria for each category, TPS minimizes variability among pathologists, resulting in improved diagnostic precision [7, 8]. This standardization is particularly crucial in the context of urothelial carcinoma, where early and precise diagnosis is paramount for effective clinical management.

Several studies and real-world examples have highlighted the effectiveness of TPS in providing a standardized and comprehensive system for urinary cytology reporting [9]. However, like any diagnostic system, TPS has areas for improvement. Challenges may arise in cases with borderline or atypical features, where the interpretation may still rely on the pathologist’s expertise. Ongoing research and feedback from clinical practice are essential for refining TPS and addressing any limitations, ensuring its continuous evolution to meet the dynamic demands of urinary cytology diagnostics.

Despite its strengths, the implementation of TPS in clinical practice is not without challenges. One notable controversy surrounds the concern of potential over-reliance on urinary cytology alone for the diagnosis of urothelial carcinoma, highlighting the need for a multimodal approach. Additionally, challenges persist in standardizing reporting across diverse clinical settings, laboratories, and pathologists. Ensuring consistent adherence to TPS criteria and overcoming interobserver variability remain ongoing challenges. Ongoing efforts are directed toward addressing these controversies and challenges, with a focus on refining TPS guidelines and fostering broader acceptance within the medical community [3].

The role of AI in urinary cytology

Currently, urine cytology is assessed through manual examination by skilled cytopathologists, who visually identify and interpret cellular abnormalities. However, the increasing volume of samples and the need for precision make automated analysis crucial. Automation ensures consistent and efficient evaluation, reducing the potential for human error and enabling faster turnaround times. Implementing automated tools, especially with the integration of AI, not only enhances diagnostic accuracy but also addresses the growing demand for streamlined and standardized urinary cytology reporting in clinical settings.

In medical diagnostics, AI emerges as a transformative force, promising heightened precision and efficiency [10]. Within urinary cytology, its applications, notably in image analysis and pattern recognition, offer enhanced capabilities for accurate diagnosis. Recent studies showcase the integration of AI tools with the TPS, underscoring their collaborative potential to refine diagnostic accuracy [11]. This synergy between AI and TPS represents a significant stride towards advancing urinary cytology as a more effective and reliable diagnostic tool.

AI advancements in urinary cytology

In this study, a systematic literature review was performed by searching PubMed until January 8, 2024, utilizing the query (“Urine”[Mesh]) AND ((“Artificial Intelligence”[Mesh]) OR (“Diagnosis, Computer-Assisted”[Mesh])). While the study protocol was not registered, deviating from the PRISMA guidelines, it was a deliberate choice as the systematic review served as a supportive tool rather than the primary focus. The aim was to offer insights into the current landscape of artificial intelligence applications in automated urine cytology analysis, providing a comprehensive understanding of the state of the field as of the specified date.

The inclusion criteria for the literature review were meticulously defined: eligible papers had to focus on urine cytology testing for potential urothelial diagnosis, employ artificial intelligence or image processing for automated image analysis, involve human materials, be published in English, and have a publication date of 2014 or later. Conversely, exclusion criteria were clearly outlined, excluding papers on urine testing for non-oncological purposes, those not assessing image analysis method performance, studies where the model only described cellular features without offering a provisional diagnosis, and those based on animal studies. This stringent criteria framework ensured a focused and relevant selection of literature aligning with the study’s objectives.

The search process in PubMed initially yielded 81 titles, which were subjected to title screening, resulting in the selection of 12 abstracts for further evaluation (fig. 1). After thorough abstract screening, 7 articles were chosen for full-text reading. To ensure a comprehensive review, 4 additional references were manually added. In total, 11 articles underwent full-text examination. Following a meticulous review, 8 articles were deemed relevant and included in the comprehensive analysis, ensuring the synthesis of the most pertinent information for the study’s objectives (tab. I).

Figure 1. PRISMA 2020 flow diagram
Table I. Overview of AI-/image-processing-assisted diagnostic approaches in urinary cytology: a comparative analysis of image analysis methods and model performance

Reference

Year

Country

Cytology / cytoblock

Automation of diagnosis

Image analysis method

Size of dataset

Golden standard

Time required for analysis

Performance of the model (best model if multiple models)

Reference

Year

Country

Cytology / cytoblock

Automation of diagnosis

Image analysis method

Size of dataset

Golden standard

Time required for analysis

Performance of the model (best model if multiple models)

Gelwan E.
et al. [12]

2019

USA

cytology slides scanned

(whole-slide images)

AI-assisted

image processing (SurePath and BCCS software)

53 slides

Lebret T.
et al. [13]

2022

France

cytology slides scanned

(whole-slide images)

automated

machine learning

(VisioCyt software)

1,360 slides:
598 training
762 validation

cytology result by pathologist

sensitivity – 85%

specificity – 81%

Lilli L.
et al. [14]

2021

Italy

cytology slides images made using digital still camera

automated

deep learning

60 slides (690 images performed, and data augmentation procedure conducted to multiply the dataset):
2,616 training
872 validation
872 testing

Nojima S.
et al. [15]

2021

Japan

cytology slides

scanned

(whole-slide images)

automated

deep learning

232 slides (divided into 61,512 images):
64% training
16% validation
20% testing

cytology result by pathologist

AUC – 0.99

F1 score – 0.90

sensitivity AI – 91%

specificity AI – 97%

accuracy AI – 95%

precision AI – 90%

Ou Y.C.
et al. [16]

2022

Taiwan

cytology slides

scanned

(whole-slide images)

AI-assisted

deep learning

150 slides:
7 training
12 validation
131 testing

Sanghvi A.B.
et al. [17]

2019

USA

cytology slides

scanned

(whole-slide images)

automated

deep learning

2,405 cytology slides:
1615 training
790 validation

cytology result by pathologist

AUC – 0.88

sensitivity – 80%

specificity – 85%

Tsuji K.
et al. [11]

2023

Japan

cytology slides

scanned

(whole-slide images)

AI-assisted

deep learning

535 slides:
181 development
39 testing cell level
315 testing slide level

117 histological slides from the same patients

cytology result by pathologist

+ comparison with subsequent histopathology results

139 s

AUC – 0.78

accuracy – 86%

prediction of HGUC in histopathology based on cytology analysis:

sensitivity:
model – 63%
pathologist – 46%
p = 0.0037

specificity:
AI – 83%
pathologist – 89%
p = 0.13

accuracy:
AI – 74%
pathologist – 68%
p = 0.08

Zhang Z.
et al. [18]

2020

China

cytology slides scanned

(whole-slide images)

automated

deep learning

49 slides:
37 training

12 testing

cytology result by pathologist

The studies included in the review exhibited diverse aims and employed varied study designs. Dataset sizes ranged widely, from 49 to 2405 cytology slides, with some studies adopting the conventional division into subsets for model development, validation, and testing. Notably, the imaging methods used varied, with one study utilizing digital still camera images and others employing whole-slide images obtained through digital pathology scanners. Despite these differences, a consistent benchmark for evaluating model performance across the majority of the studies was maintained; the comparison to previous assessments conducted by experienced cytopathologists served as the universally recognized golden standard in all instances.

Among the eight studies included, three specifically focused on AI-assisted methods for the detection of high-grade urothelial carcinoma cells or atypical cells. The predominant trend observed in most of the published research involved the utilization of deep learning models to automate predicted diagnoses. Notably, only one of the studies employed classical image processing methods, indicating a prevalent reliance on advanced deep learning approaches for the development and implementation of AI in automated urine cytology analysis.

The evaluation of model performance in the study encompassed various metrics, with most studies reporting the area under the curve (AUC). The AUC is a metric used in binary classification models, representing the ability of the model to distinguish between positive and negative instances. It ranges from 0 to 1, with a higher AUC indicating better discriminatory power. In the presented studies, the AUC values of the developed models ranged from 0.78 to 0.99, suggesting a high level of accuracy. Additionally, specificity, indicating the model’s ability to correctly identify negative instances, varied between 83% and 85%, while sensitivity, reflecting the model’s capability to identify positive instances, ranged from 63% to 97%. These metrics collectively provided a comprehensive assessment of the models’ discriminatory performance and diagnostic accuracy in automated urine cytology analysis.

While AI advancements in urinary cytology exhibit promise, the heterogeneity in study methodologies and dataset sizes raises concerns about generalizability. The reliance on deep learning without classical image processing warrants scrutiny, as the field may benefit from a more balanced exploration of diverse methodologies. Additionally, the high AUC values suggest robust discriminatory power, yet skepticism lingers over potential overfitting to specific datasets. Despite these reservations, the transformative potential of AI in urothelial carcinoma diagnostics is evident, but careful consideration and validation are crucial in ensuring the reliability and applicability of these models in diverse clinical scenarios.

Challenges, considerations, and future directions

The integration of AI tools in urinary cytology reporting brings forth potential challenges. One significant hurdle is the need for robust datasets that encompass the diverse spectrum of urinary cytology specimens. Limited datasets may hinder the AI’s ability to accurately identify nuanced patterns or rare abnormalities. Additionally, the interpretability of AI-generated results poses a challenge, as understanding the underlying decision-making process of complex algorithms is crucial to gain trust in their clinical application. Ensuring the seamless integration of AI into existing laboratory workflows and addressing issues related to standardization and validation are key challenges that must be overcome to realize the full potential of AI in urinary cytology reporting.

Successful implementation of AI tools in urinary cytology reporting hinges on collaborative efforts between pathologists, clinicians, and AI developers. Establishing a strong synergy among these stakeholders is essential for tailoring AI algorithms to meet the specific needs of urinary cytology diagnostics. Collaborative endeavors foster a mutual understanding of the clinical context and intricacies of pathology, enabling AI developers to design algorithms that align with the nuanced decision-making processes of pathologists. Continuous communication and feedback loops ensure that AI tools are refined based on real-world clinical experiences, optimizing their performance over time. This collaborative approach not only accelerates the development and validation of AI algorithms but also enhances their acceptance and integration into routine clinical practice, ultimately improving diagnostic accuracy and patient outcomes.

Conclusions

In summary, the critical review underscores the transformative impact of the TPS in addressing historical challenges and providing a standardized framework. TPS enhances diagnostic precision, reduces subjectivity, and improves communication between pathologists and clinicians [19]. The integration of AI introduces exciting prospects, but the prevailing reliance on advanced algorithms raises concerns about potential overfitting and limited exploration of alternative methodologies. The collaboration between TPS and AI shows promise, but a cautious approach is essential to ensure the reliability and applicability of these advancements across diverse clinical scenarios.

Article information and declarations

Author contributions

Irmina M. Michałek conceptualization, literature analysis, writing original draft, writing review and editing.

Monika Durzyńska writing review and editing.

Florentino L. Caetano dos Santos literature analysis, writing review and editing.

Conflict of interest

None declared

Irmina M. Michałek

Maria Sklodowska-Curie National Research Institute of Oncology

Department of Pathology

ul. Roentgena 5

02-781 Warszawa, Poland

e-mail: irmina.michalek@nio.gov.pl

Received: 18 Jan 2024

Accepted: 9 Apr 2024

References

  1. Babjuk M, Burger M, Capoun O, et al. European Association of Urology Guidelines on Non-muscle-invasive Bladder Cancer (Ta, T1, and Carcinoma in Situ). Eur Urol. 2022; 81(1): 7594, doi: 10.1016/j.eururo.2021.08.010, indexed in Pubmed: 34511303.
  2. Barkan G, Wojcik E, Nayar R, et al. The Paris System for Reporting Urinary Cytology: The Quest to Develop a Standardized Terminology. Adv Anat Pathol. 2016; 23(4): 193201, doi: 10.1097/pap.0000000000000118, indexed in Pubmed: 27233050.
  3. Wojcik EM, Kurtycz DFI, Rosenthal DL. We’ll always have Paris The Paris System for Reporting Urinary Cytology 2022. J Am Soc Cytopathol. 2022; 11(2): 6266, doi: 10.1016/j.jasc.2021.12.003, indexed in Pubmed: 35094954.
  4. Kurtycz DFI, Sundling KE, Barkan GA. The Paris system of Reporting Urinary Cytology: Strengths and opportunities. Diagn Cytopathol. 2020; 48(10): 890895, doi: 10.1002/dc.24561, indexed in Pubmed: 32780564.
  5. Meilleroux J, Daniel G, Aziza J, et al. One year of experience using the Paris System for Reporting Urinary Cytology. Cancer Cytopathol. 2018; 126(6): 430436, doi: 10.1002/cncy.21999, indexed in Pubmed: 29663682.
  6. Bakkar R, Mirocha J, Fan X, et al. Impact of the Paris system for reporting urine cytopathology on predictive values of the equivocal diagnostic categories and interobserver agreement. Cytojournal. 2019; 16: 21, doi: 10.4103/cytojournal.cytojournal_30_19, indexed in Pubmed: 31741668.
  7. Long T, Layfield LJ, Esebua M, et al. Interobserver reproducibility of The Paris System for Reporting Urinary Cytology. Cytojournal. 2017; 14: 17, doi: 10.4103/cytojournal.cytojournal_12_17, indexed in Pubmed: 28828030.
  8. Kurtycz DFI, Barkan GA, Pavelec DM, et al. Paris Interobserver Reproducibility Study (PIRST). J Am Soc Cytopathol. 2018; 7(4): 174184, doi: 10.1016/j.jasc.2018.02.005, indexed in Pubmed: 31043274.
  9. Kurtycz DFI, Wojcik EM, Rosenthal DL. Perceptions of Paris: an international survey in preparation for The Paris System for Reporting Urinary Cytology 2.0 (TPS 2.0). J Am Soc Cytopathol. 2023; 12(1): 6674, doi: 10.1016/j.jasc.2022.09.002, indexed in Pubmed: 36274039.
  10. Niazi MK, Parwani AV, Gurcan MN. Digital pathology and artificial intelligence. Lancet Oncol. 2019; 20(5): e253e261, doi: 10.1016/S1470-2045(19)30154-8, indexed in Pubmed: 31044723.
  11. Tsuji K, Kaneko M, Harada Y, et al. A Fully Automated Artificial Intelligence System to Assist Pathologists’ Diagnosis to Predict Histologically High-grade Urothelial Carcinoma from Digitized Urine Cytology Slides Using Deep Learning. Eur Urol Oncol. 2024; 7(2): 258265, doi: 10.1016/j.euo.2023.11.009, indexed in Pubmed: 38065702.
  12. Gelwan E, Zhang ML, Allison DB, et al. Variability among observers utilizing the CellSolutions BestCyte Cell Sorter imaging system for the assessment of urinary tract cytology specimens. J Am Soc Cytopathol. 2019; 8(1): 1826, doi: 10.1016/j.jasc.2018.10.001, indexed in Pubmed: 30929755.
  13. Lebret T, Pignot G, Colombel M, et al. Artificial intelligence to improve cytology performances in bladder carcinoma detection: results of the VisioCyt test. BJU Int. 2022; 129(3): 356363, doi: 10.1111/bju.15382, indexed in Pubmed: 33751774.
  14. Lilli L, Giarnieri E, Scardapane S. A Calibrated Multiexit Neural Network for Detecting Urothelial Cancer Cells. Comput Math Methods Med. 2021; 2021: 5569458, doi: 10.1155/2021/5569458, indexed in Pubmed: 34234839.
  15. Nojima S, Terayama K, Shimoura S, et al. A deep learning system to diagnose the malignant potential of urothelial carcinoma cells in cytology specimens. Cancer Cytopathol. 2021; 129(12): 984995, doi: 10.1002/cncy.22443, indexed in Pubmed: 33979039.
  16. Ou YC, Tsao TY, Chang MC, et al. Evaluation of an artificial intelligence algorithm for assisting the Paris System in reporting urinary cytology: A pilot study. Cancer Cytopathol. 2022; 130(11): 872880, doi: 10.1002/cncy.22615, indexed in Pubmed: 35727052.
  17. Sanghvi AB, Allen EZ, Callenberg KM, et al. Performance of an artificial intelligence algorithm for reporting urine cytopathology. Cancer Cytopathol. 2019; 127(10): 658666, doi: 10.1002/cncy.22176, indexed in Pubmed: 31412169.
  18. Zhang Z, Fu X, Liu J, et al. Developing a Machine Learning Algorithm for Identifying Abnormal Urothelial Cells: A Feasibility Study. Acta Cytol. 2021; 65(4): 335341, doi: 10.1159/000510474, indexed in Pubmed: 33022673.
  19. Nikas IP, Seide S, Proctor T, et al. The Paris System for Reporting Urinary Cytology: A Meta-Analysis. J Pers Med. 2022; 12(2), doi: 10.3390/jpm12020170, indexed in Pubmed: 35207658.