open access

Vol 48, No 5 (2016)
Letters to editor
Published online: 2016-10-27
Submitted: 2016-09-08
Accepted: 2016-09-30
Get Citation

Successful retrieval of a knotted Swan-Ganz catheter using interventional approach in an adult: a case report

Xiao-ke Shang, Yan Yan, Bin Wang
DOI: 10.5603/AIT.a2016.0048
·
Pubmed: 27785780
·
Anaesthesiol Intensive Ther 2016;48(5):367-370.

open access

Vol 48, No 5 (2016)
Letters to editor
Published online: 2016-10-27
Submitted: 2016-09-08
Accepted: 2016-09-30

Abstract

Not available

Abstract

Not available
Get Citation
About this article
Title

Successful retrieval of a knotted Swan-Ganz catheter using interventional approach in an adult: a case report

Journal

Anaesthesiology Intensive Therapy

Issue

Vol 48, No 5 (2016)

Pages

367-370

Published online

2016-10-27

DOI

10.5603/AIT.a2016.0048

Pubmed

27785780

Bibliographic record

Anaesthesiol Intensive Ther 2016;48(5):367-370.

Authors

Xiao-ke Shang
Yan Yan
Bin Wang

References (13)
  1. Shang Xk, Yan Y, Wang B. Successful retrieval of a knotted Swan- -Ganz catheter using interventional approach in an adult: a case report. Anestezjologia Intensywna Terapia. 2016; 48(5): 367–370.
  2. Gidwani UK, Mohanty B, Chatterjee K. The pulmonary artery catheter: a critical reappraisal. Cardiol Clin. 2013; 31(4): 545–565.
  3. Aggarwal N, Kupfer Y, Yoon TS, et al. Pulmonary artery catheter coiled in the main pulmonary artery trunk. BMJ Case Rep. 2013.
  4. Starzyk L, Yao E, Roche-Nagel G, et al. Snaring swans: intraoperative knotting of pulmonary artery catheters. Anaesthesiol Intensive Ther. 2016; 48(1): 66–70.
  5. Swan HJ, Ganz W, Forrester J, et al. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970; 283(9): 447–451.
  6. Palmieri TL. The inventors of the Swan-Ganz catheter: H. J. C. Swan and William Ganz. Curr Surg. 2003; 60(3): 351–352.
  7. Binanay C, Califf RM, Hasselblad V, et al. ESCAPE Investigators and ESCAPE Study Coordinators. Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA. 2005; 294(13): 1625–1633.
  8. Harvey S, Harrison DA, Singer M, et al. PAC-Man study collaboration. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet. 2005; 366(9484): 472–477.
  9. Narumiya C, Isobe F. [Insertion procedure of the Swan-Ganz catheter]. Kyobu Geka. 2010; 63(8 Suppl): 607–611.
  10. Fleisher AG, Tyers GF, Manning GT, et al. Management of massive hemoptysis secondary to catheter-induced perforation of the pulmonary artery during cardiopulmonary bypass. Chest. 1989; 95(6): 1340–1341.
  11. Kearney TJ, Shabot MM. Pulmonary artery rupture associated with the Swan-Ganz catheter. Chest. 1995; 108(5): 1349–1352.
  12. Chemchik H, Hassen MB, Turki M, et al. [Intracardiac node of Swan-Ganz catheter: report of a case]. Pan Afr Med J. 2013; 14: 137.
  13. Lopes MC, de Cleva R, Zilberstein B, et al. Pulmonary artery catheter complications: report on a case of a knot accident and literature review. Rev Hosp Clin Fac Med Sao Paulo. 2004; 59(2): 77–85.

Important: This website uses cookies. More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.