Abstract

Physicians in the field of respiratory medicine are particularly concerned about the availability of a reliable diagnostic tool to investigate respiratory allergy. Usually, basophils are easy to obtain from peripheral blood and therefore they represent a reproducible model to assess allergy in individuals. Cell assays called basophil activation tests (BATs) are widespread tools for allergy diagnosis and are easily available in most of the medical labs. The strategy by which basophils are captured in a flow cytometry protocol has met many suggestions, recommendations and experimental novelties in recent years, yet the debate needs to be further expanded. Concerns still remain about the suitability of the many approaches to make the basophil activation test (BAT) an excellent and practical tool to diagnose allergy, while improving its analytical performance. This technical report describes the methodological aspects of the use of the protocol adopting the panel CD45dim/CD123bright/HLA-DRneg to gate basophils in flow cytometry, trying to highlight the main biases related to an incorrect use of this protocol.

Abstract

Physicians in the field of respiratory medicine are particularly concerned about the availability of a reliable diagnostic tool to investigate respiratory allergy. Usually, basophils are easy to obtain from peripheral blood and therefore they represent a reproducible model to assess allergy in individuals. Cell assays called basophil activation tests (BATs) are widespread tools for allergy diagnosis and are easily available in most of the medical labs. The strategy by which basophils are captured in a flow cytometry protocol has met many suggestions, recommendations and experimental novelties in recent years, yet the debate needs to be further expanded. Concerns still remain about the suitability of the many approaches to make the basophil activation test (BAT) an excellent and practical tool to diagnose allergy, while improving its analytical performance. This technical report describes the methodological aspects of the use of the protocol adopting the panel CD45dim/CD123bright/HLA-DRneg to gate basophils in flow cytometry, trying to highlight the main biases related to an incorrect use of this protocol.

Get Citation

Keywords

basophil activation test, allergy, CD123, flow cytometry

About this article
Title

Using a CD45dim/CD123bright/HLA-DRneg phenotyping protocol to gate basophils in FC for airway allergy. CD123 does not decrease

Journal

Advances in Respiratory Medicine

Issue

Vol 85, No 4 (2017)

Pages

193-201

Published online

2017-09-01

DOI

10.5603/ARM.2017.0032

Bibliographic record

Adv Respir Med 2017;85(4):193-201.

Keywords

basophil activation test
allergy
CD123
flow cytometry

Authors

Salvatore Chirumbolo
Geir Bjorklund
Antonio Vella

Important: This website uses cookies.tanya dokter More >>

The cookies allow us to identify your computer and find out details about your last visit. They remembering whether you've visited the site before, so that you remain logged in - or to help us work out how many new website visitors we get each month. Most internet browsers accept cookies automatically, but you can change the settings of your browser to erase cookies or prevent automatic acceptance if you prefer.

Czasopismo Pneumonologia i Alergologia Polska dostęne jest również w Ikamed - księgarnia medyczna

Wydawcą serwisu jest "Via Medica sp. z o.o." sp.k., ul. Świętokrzyska 73, 80–180 Gdańsk

tel.:+48 58 320 94 94, faks:+48 58 320 94 60, e-mail: viamedica@viamedica.pl